ABB

Circuit breaker S200MUC 2P B6 10kA DC - ABB2CDS272061R0065

ABB2CDS272061R0065

€53.18 Excl. Tax
€63.82 Inc. Tax
available In stock – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 250€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa payplug fintecture alma applepay
Technical informations
Power supply connection: Please note polarity
Connecting capacity:
Busbar: 10/10 mm² Rigid
Installation size: 2 modules (DIN 43880)
Degree of protection: IP20 (IP40 with cover)
Overvoltage category: III
Pollution degree: 3
Ambient temperature (operation): -25 to +55 °C
Ambient temperature (storage): -40 to +70 °C
Vibration resistance: 5g (5...150...5 Hz, 20 cycles, 0.8 In)
Shock resistance: 25g (2 shocks, 13 ms)
Humidity resistance: 28 cycles ? 55 °C / 90-96% and 25 °C / 95-100%
Dimensions (W x H x D): 35 mm x 88 mm x 69 mm
Built-in depth: 69 mm
Net weight: 0.25 kg
Weight per pole: 0.125 kg
UL/CSA max operating voltage: 480Y / 277 V AC, 500 V DC
Interrupting rating (UL1077): Up to 10 kA
UL/CSA connecting capacity:
UL/CSA tightening torque: 25 in·lb
RoHS compliance: Yes (Directive 2011/65/EU + 2015/863)
RoHS declaration date: 2011-06-08
REACH compliance: Yes (? 0.1% mass)
REACH declaration date: 2024-08-21
SCIP ID: cec6beff-be12-4313-bcef-0d0cbaa3ae87
WEEE category: 5 ? Small equipment
Usage type: B2B
Busbar: 14?8 AWG Conductor
Busbar: 10/10 mm²
Rigid: 0.75?35 mm²
Flexible: 0.75?25 mm²
Flexible with ferrule: 0.75?25 mm²
Stranded: 0.75?35 mm²
Rated current (In): 6 A
Number of poles: 2P
Number of protected poles: 2
Tripping characteristic: Z (also available as B)
Rated insulation voltage (Ui): 440 V (IEC/EN 60664-1)
Rated operational voltage: 12?440 V AC / 12?500 V DC
Impulse withstand voltage (Uimp): 4?6.2 kV depending on altitude
Voltage type: AC/DC
Rated frequency: 50 / 60 Hz
Energy limitation class: 3
Ultimate short-circuit breaking capacity (Icu): up to 25 kA
Service short-circuit breaking capacity (Ics): up to 20 kA
Rated short-circuit capacity: 10 kA (AC)
Conditional short-circuit current (Inc): 15 kA
Dielectric test voltage: 2 kV / 1 min / 50?60 Hz
Contact position indication: Red ON / Green OFF
Actuator marking: I / O
Actuator material: Insulation Group II, black, sealable
Tightening torque: 2.8 N·m
Terminal type: Screw terminals
Screw terminal type: Bi-directional cylinder-lift (failsafe)
Recommended screwdriver: Pozidriv 2
Mechanical endurance: 20,000 cycles
Electrical endurance: 20,000 cycles (AC)
Power loss: 4.06 W total (2.03 W per pole)
Accessories available: Yes
Remarks: Please note polarity of device
In short
Reference ABB2CDS272061R0065
Product Name Circuit breaker S200MUC 2P B6 10kA DC - ABB2CDS272061R0065
Related Categories