
calcActive())">
ABB
Circuit breaker S200MUC 2P B6 10kA DC - ABB2CDS272061R0065
ABB2CDS272061R0065
€53.18 Excl. Tax
€63.82 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 250€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
| Power supply connection: | Please note polarity |
|---|---|
| Connecting capacity: | |
| Busbar: | 10/10 mm² Rigid |
| Installation size: | 2 modules (DIN 43880) |
| Degree of protection: | IP20 (IP40 with cover) |
| Overvoltage category: | III |
| Pollution degree: | 3 |
| Ambient temperature (operation): | -25 to +55 °C |
| Ambient temperature (storage): | -40 to +70 °C |
| Vibration resistance: | 5g (5...150...5 Hz, 20 cycles, 0.8 In) |
| Shock resistance: | 25g (2 shocks, 13 ms) |
| Humidity resistance: | 28 cycles ? 55 °C / 90-96% and 25 °C / 95-100% |
| Dimensions (W x H x D): | 35 mm x 88 mm x 69 mm |
| Built-in depth: | 69 mm |
| Net weight: | 0.25 kg |
| Weight per pole: | 0.125 kg |
| UL/CSA max operating voltage: | 480Y / 277 V AC, 500 V DC |
| Interrupting rating (UL1077): | Up to 10 kA |
| UL/CSA connecting capacity: | |
| UL/CSA tightening torque: | 25 in·lb |
| RoHS compliance: | Yes (Directive 2011/65/EU + 2015/863) |
| RoHS declaration date: | 2011-06-08 |
| REACH compliance: | Yes (? 0.1% mass) |
| REACH declaration date: | 2024-08-21 |
| SCIP ID: | cec6beff-be12-4313-bcef-0d0cbaa3ae87 |
| WEEE category: | 5 ? Small equipment |
| Usage type: | B2B |
| Busbar: | 14?8 AWG Conductor |
| Busbar: | 10/10 mm² |
| Rigid: | 0.75?35 mm² |
| Flexible: | 0.75?25 mm² |
| Flexible with ferrule: | 0.75?25 mm² |
| Stranded: | 0.75?35 mm² |
| Rated current (In): | 6 A |
|---|---|
| Number of poles: | 2P |
| Number of protected poles: | 2 |
| Tripping characteristic: | Z (also available as B) |
| Rated insulation voltage (Ui): | 440 V (IEC/EN 60664-1) |
| Rated operational voltage: | 12?440 V AC / 12?500 V DC |
| Impulse withstand voltage (Uimp): | 4?6.2 kV depending on altitude |
| Voltage type: | AC/DC |
| Rated frequency: | 50 / 60 Hz |
| Energy limitation class: | 3 |
| Ultimate short-circuit breaking capacity (Icu): | up to 25 kA |
| Service short-circuit breaking capacity (Ics): | up to 20 kA |
| Rated short-circuit capacity: | 10 kA (AC) |
| Conditional short-circuit current (Inc): | 15 kA |
| Dielectric test voltage: | 2 kV / 1 min / 50?60 Hz |
| Contact position indication: | Red ON / Green OFF |
| Actuator marking: | I / O |
| Actuator material: | Insulation Group II, black, sealable |
| Tightening torque: | 2.8 N·m |
| Terminal type: | Screw terminals |
| Screw terminal type: | Bi-directional cylinder-lift (failsafe) |
| Recommended screwdriver: | Pozidriv 2 |
| Mechanical endurance: | 20,000 cycles |
| Electrical endurance: | 20,000 cycles (AC) |
| Power loss: | 4.06 W total (2.03 W per pole) |
| Accessories available: | Yes |
| Remarks: | Please note polarity of device |
In short
Reference ABB2CDS272061R0065
Product Name Circuit breaker S200MUC 2P B6 10kA DC - ABB2CDS272061R0065
Related Categories
