Technical informations
| Ambient Air Temperature: | |
|---|---|
| In operation : | -25 to +55 °C |
| In storage : | -40 to +70 °C |
| Degree of protection : | IP20 |
| Enclosure with cover : | IP40 |
| Pollution degree : | 3 |
| Climatic conditions : | 28 cycles at 55 °C (90?96%) and 25 °C (95?100%) |
| Vibration resistance : | 20 cycles with 0.8 In load: 5g, 5-150-5 Hz |
| Shock resistance (IEC 60068-2-27) : | 25g, 2 shocks of 13 ms |
| Environmental reference : | 2CDK400030D201 |
| Width in modular spacings : | 2 |
| Product net width : | 35 mm |
| Product net height : | 88 mm |
| Product net depth / length : | 69 mm |
| Product net weight : | 0.25 kg |
| Pole net weight : | 0.125 kg |
| Built-in depth (t2) : | 69 mm |
| Breaking capacity Icu: | 220 V DC - 25 kA / 230 V AC - 15 kA / 400 V AC - 15 kA / 440 V AC - 10 kA / 440 V DC - 10 kA / 230 V - 10 kA |
|---|---|
| Breaking capacity Ics: | 220 V DC - 20 kA / 230 V AC - 10 kA |
| Power supply connection: | Respect the polarity of the device |
| Contact position indicator: | Red = ON / Green = OFF |
| Energy limitation class: | 3 |
| Mechanical endurance: | 20,000 cycles |
| Number of protected poles: | 2 |
| Number of poles: | 2P |
| Tightening torque: | 2.8 N·m |
| Terminal type: | Bidirectional cylindrical lift screw terminal |
| Actuator marking: | I / O |
| Actuator material: | Group II insulation, black, sealable |
| Options: | Universal current |
| Recommended screwdriver: | Pozidriv 2 |
| Available accessories: | Yes |
| Notes: | Respect the polarity of the device |
| Connection capacity: | Busbar 10/10 mm² / Flexible with ferrule |
| Installation dimensions: | According to DIN 43880 - 1 module |
| Terminal type: | Screw terminals |
| Tripping characteristic: | Z |
| Assigned service voltage: | 400 V AC (IEC 60898-1) / 440 V AC - 440 V DC (IEC 60947-2) |
| Assigned insulation voltage (Ui): | 440 V (IEC/EN 60664-1) |
| Nominal impulse withstand voltage (Uimp): | 4 kV (5 kV at 2000 m / 6.2 kV at sea level) |
| Input voltage type: | AC / DC |
| Assigned current (In): | 2 A |
| Assigned short-circuit capacity: | 10 kA (AC / 230 V / 400 V / 440 V DC) |
| Assigned conditional short-circuit current (Inc): | 15 kA (230 V / 400 V) |
| Nominal frequency: | 50 / 60 Hz, DC |
| Power losses: | 5.4 W / 2.7 W per pole |
| Surge category: | III |
| Enclosure material: | Group I insulation, RAL 7035 |
| Max. UL/CSA voltage: | 480Y/277 V AC / 500 V DC |
| UL1077 breaking capacity: | 220 V AC - 10 kA / 277 V AC - 6 kA / 440 V DC - 10 kA / 480Y - 10 kA / 500 V DC - 10 kA |
| UL/CSA connection capacity: | Busbar 14-8 AWG / Conductor 14-4 AWG |
| UL/CSA tightening torque: | 25 in·lb |