Technical informations
Ambient Air Temperature:
In operation : -25 to +55 °C
In storage : -40 to +70 °C
Degree of protection : IP20
Enclosure with cover : IP40
Pollution degree : 3
Climatic conditions : 28 cycles at 55 °C (90?96%) and 25 °C (95?100%)
Vibration resistance : 20 cycles with 0.8 In load: 5g, 5-150-5 Hz
Shock resistance (IEC 60068-2-27) : 25g, 2 shocks of 13 ms
Environmental reference : 2CDK400030D201
Width in modular spacings : 2
Product net width : 35 mm
Product net height : 88 mm
Product net depth / length : 69 mm
Product net weight : 0.25 kg
Pole net weight : 0.125 kg
Built-in depth (t2) : 69 mm
Breaking capacity Icu: 220 V DC - 25 kA / 230 V AC - 15 kA / 400 V AC - 15 kA / 440 V AC - 10 kA / 440 V DC - 10 kA / 230 V - 10 kA
Breaking capacity Ics: 220 V DC - 20 kA / 230 V AC - 10 kA
Power supply connection: Respect the polarity of the device
Contact position indicator: Red = ON / Green = OFF
Energy limitation class: 3
Mechanical endurance: 20,000 cycles
Number of protected poles: 2
Number of poles: 2P
Tightening torque: 2.8 N·m
Terminal type: Bidirectional cylindrical lift screw terminal
Actuator marking: I / O
Actuator material: Group II insulation, black, sealable
Options: Universal current
Recommended screwdriver: Pozidriv 2
Available accessories: Yes
Notes: Respect the polarity of the device
Connection capacity: Busbar 10/10 mm² / Flexible with ferrule
Installation dimensions: According to DIN 43880 - 1 module
Terminal type: Screw terminals
Tripping characteristic: Z
Assigned service voltage: 400 V AC (IEC 60898-1) / 440 V AC - 440 V DC (IEC 60947-2)
Assigned insulation voltage (Ui): 440 V (IEC/EN 60664-1)
Nominal impulse withstand voltage (Uimp): 4 kV (5 kV at 2000 m / 6.2 kV at sea level)
Input voltage type: AC / DC
Assigned current (In): 2 A
Assigned short-circuit capacity: 10 kA (AC / 230 V / 400 V / 440 V DC)
Assigned conditional short-circuit current (Inc): 15 kA (230 V / 400 V)
Nominal frequency: 50 / 60 Hz, DC
Power losses: 5.4 W / 2.7 W per pole
Surge category: III
Enclosure material: Group I insulation, RAL 7035
Max. UL/CSA voltage: 480Y/277 V AC / 500 V DC
UL1077 breaking capacity: 220 V AC - 10 kA / 277 V AC - 6 kA / 440 V DC - 10 kA / 480Y - 10 kA / 500 V DC - 10 kA
UL/CSA connection capacity: Busbar 14-8 AWG / Conductor 14-4 AWG
UL/CSA tightening torque: 25 in·lb