Technical informations
Enclosure material: Insulation group I, RAL 7035
Maximum operating voltage UL/CSA: 480Y/277 V AC, 500 V DC
Breaking capacity according to UL1077: (220 V AC) 10 kA (277 V AC) 6 kA (440 V DC) 10 kA (480Y / 277 V AC) 10 kA (500 V DC) 10 kA
Connection capacity UL/CSA:
Tightening torque UL/CSA: 25 in·lb
Dielectric test voltage: 50 / 60 Hz - 1 min 2 kV
Nominal short-circuit breaking capacity (Icu): (220 V DC) 25 kA (230 V AC) 15 kA (400 V AC) 15 kA (440 V AC) 10 kA (440 V DC) 10 kA (230 V) 10 kA
Nominal service short-circuit breaking capacity (Ics):
Current connection: Follow the device polarity
Contact position indicator: Red ON / Green OFF
Energy limiting class: 3
Electrical lifespan: 20000 AC cycles
Mechanical lifespan: 20000 cycles
Number of protected poles: 2
Number of poles: 2P
Tightening torque: 2.8 N·m
Screw connection type: Error-proof bi-directional cylinder connection
Actuator marking: I / O
Actuator material: Insulation group II, black, lockable
Available options: Universal current
Recommended screwdriver: Pozidriv 2
Available accessories: Yes
Notes: Follow the device polarity
Connection capacity: Busbar 10/10 mm² Flexible with ferrule 0.75 ... 25 mm² Flexible 0.75 ... 25 mm² Rigid 0.75 ... 35 mm² Braid 0.75 ... 35 mm²
Installation size: According to DIN 43880 1
Terminal type: Screw connections
Switch characteristic: B
Nominal operating voltage: according to IEC 60898-1 400 V AC according to IEC 60898-1 440 V DC according to IEC 60898-2 400 V AC according to IEC 60898-2 440 V DC according to IEC 60947-2 440 V AC according to IEC 60947-2 440 V DC
Operating voltage: Maximum (including tolerances) 440 V AC Maximum (including tolerances) 500 V DC Minimum 12 V AC Minimum 12 V DC
Nominal insulation voltage (Ui): according to IEC/EN 60664-1 440 V
Nominal impulse withstand voltage (Uimp): 4 kV
Input voltage type: AC/DC
Nominal current (In): 25 A
Nominal short-circuit capacity: (AC) 10 kA (230 V AC) 10 kA (253 V AC) 10 kA (400 V AC) 10 kA (440 V DC) 10 kA (230 V) 10 kA (400 V) 10 kA
Nominal conditional short-circuit current (Inc): (230 V) 15 kA (400 V) 15 kA
Nominal frequency (f): 50 / 60 Hz DC
Power loss: 5.76 W per pole under nominal operating conditions 2.88 W
Overvoltage category: III
In short