SCHNEIDER
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 115 V AC 50/60 Hz coil - LC1DT60A6FE7
LC1DT60A6FE7
This product is no longer available. Contact us for a suitable replacement solution tailored to your needs.
Technical informations
| Range of product: | TeSys D |
|---|---|
| Range: | TeSys |
| Product name: | TeSys D |
| Product or component type: | Contactor |
| Device short name: | LC1D |
| Contactor application: | Resistive load |
| Utilisation category: | AC-1 |
| Poles description: | 4P |
| Pole contact composition: | 4 NO |
| [Ue] rated operational voltage: | Power circuit: Power circuit: |
| [Ie] rated operational current: | 60Â A (at |
| Control circuit type: | AC at 50/60 Hz |
| [Uc] control circuit voltage: | 115 V AC 50/60 Hz |
| Auxiliary contact composition: | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage: | 6Â kV conforming to IEC 60947 |
| Overvoltage category: | III |
| [Ith] conventional free air thermal current: | 10 A (at 60 °C) for signalling circuit60 A (at 60 °C) for power circuit |
| Irms rated making capacity: | 140Â A AC for signalling circuit conforming to IEC 60947-5-1250Â A DC for signalling circuit conforming to IEC 60947-5-1800Â A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity: | 800Â A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current: | 320 A 40 °C - 10 s for power circuit720 A 40 °C - 1 s for power circuit72 A 40 °C - 10 min for power circuit165 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| Associated fuse rating: | 10Â A gG for signalling circuit conforming to IEC 60947-5-180Â A gG at 80Â A gG at |
| Average impedance: | 1.6Â mOhm - Ith 60Â A 50 Hz for power circuit |
| [Ui] rated insulation voltage: | Power circuit: 600Â V CSA certifiedPower circuit: 600Â V UL certifiedSignalling circuit: 690Â V conforming to IEC 60947-1Signalling circuit: 600Â V CSA certifiedSignalling circuit: 600Â V UL certifiedPower circuit: 690Â V conforming to IEC 60947-4-1 |
| Electrical durability: | 1.4Â Mcycles 60Â A AC-1 at Ue |
| Power dissipation per pole: | 5.8Â W AC-1 |
| Protective cover: | With |
| Mounting support: | RailPlate |
| Standards: | CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508 |
| Product certifications: | GOSTDNVRINALROS (Lloyds register of shipping)GLBVULCSACCC |
| Connections - terminals: | Control circuit: lugs-ring terminals (external diameter: 8Â mm) Power circuit: lugs-ring terminals (external diameter: 16.5Â mm) |
| Tightening torque: | Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5Power circuit: 6 N.m - on lugs-ring terminals M6 |
| Operating time: | 4...19 ms opening12...26 ms closing |
| Safety reliability level: | B10d = 1369863Â cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000Â cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability: | 6Â Mcycles |
| Maximum operating rate: | 3600 cyc/h 60 °C |
| Coil technology: | Without built-in suppressor module |
|---|---|
| Control circuit voltage limits: | 0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.1 Uc (-40...60 °C):operational AC 50 Hz0.85...1.1 Uc (-40...60 °C):operational AC 60 Hz1...1.1 Uc (60...70 °C):operational AC 50/60 Hz |
| Inrush power in VA: | 140 VA 60 Hz cos phi 0.75 (at 20 °C)160 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA: | 13 VA 60 Hz cos phi 0.3 (at 20 °C)15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation: | 4...5Â W at 50/60 Hz |
| Auxiliary contacts type: | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency: | 25...400 Hz |
| Minimum switching current: | 5Â mA for signalling circuit |
| Minimum switching voltage: | 17Â V for signalling circuit |
| Non-overlap time: | 1.5Â ms on de-energisation between NC and NO contact1.5Â ms on energisation between NC and NO contact |
| Insulation resistance: | > 10 MOhm for signalling circuit |
| Contact compatibility: | M6 |
| Compatibility code: | LC1D |
In short
Reference LC1DT60A6FE7
Product Name TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 60 A - 115 V AC 50/60 Hz coil - LC1DT60A6FE7
Range TeSys
Related Categories