Technical informations
| Range of product: | TeSys DTeSys Deca |
|---|---|
| Range: | TeSysTeSys Deca |
| Product name: | TeSys DTeSys Deca |
| Product or component type: | Reversing contactor |
| Device short name: | LC2D |
| Contactor application: | Resistive loadMotor control |
| Utilisation category: | AC-1AC-3 |
| Device presentation: | Preassembled with reversing power busbar |
| Poles description: | 3P |
| Pole contact composition: | 3 NO |
| [Ue] rated operational voltage: | Power circuit: Power circuit: |
| [Ie] rated operational current: | 9Â A (at 25Â A (at |
| Motor power kW: | 2.2Â kW at 220...230 V AC 50 Hz4Â kW at 380...400 V AC 50 Hz4Â kW at 415...440 V AC 50 Hz5.5Â kW at 500 V AC 50 Hz5.5Â kW at 660...690 V AC 50 Hz |
| Motor power hp: | 0.5Â hp at 115 V AC 60 Hz for 1 phase motors1Â hp at 230/240 V AC 60 Hz for 1 phase motors2Â hp at 200/208 V AC 60 Hz for 3 phases motors2Â hp at 230/240 V AC 60 Hz for 3 phases motors5Â hp at 460/480 V AC 60 Hz for 3 phases motors7.5Â hp at 575/600 V AC 60 Hz for 3 phases motors |
| Control circuit type: | DC low consumption |
| [Uc] control circuit voltage: | 24 V DC |
| Auxiliary contact composition: | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage: | 6Â kV conforming to IEC 60947 |
| Overvoltage category: | III |
| [Ith] conventional free air thermal current: | 10 A (at 60 °C) for signalling circuit25 A (at 60 °C) for power circuit |
| Irms rated making capacity: | 250Â A at 440 V for power circuit conforming to IEC 60947140Â A AC for signalling circuit conforming to IEC 60947-5-1250Â A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity: | 250Â A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current: | 30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit |
| Associated fuse rating: | 25Â A gG at 20Â A gG at 10Â A gG for signalling circuit conforming to IEC 60947-5-1 |
| Average impedance: | 2.5Â mOhm - Ith 25Â A 50 Hz for power circuit |
| [Ui] rated insulation voltage: | Power circuit: 690Â V conforming to IEC 60947-4-1Power circuit: 600Â V CSA certifiedPower circuit: 600Â V UL certifiedSignalling circuit: 690Â V conforming to IEC 60947-1Signalling circuit: 600Â V CSA certifiedSignalling circuit: 600Â V UL certified |
| Electrical durability: | 0.6Â Mcycles 25Â A AC-1 at Ue 2Â Mcycles 9Â A AC-3 at Ue |
| Power dissipation per pole: | 0.2Â W AC-31.56Â W AC-1 |
| Protective cover: | With |
| Interlocking type: | Mechanical |
| Mounting support: | PlateRail |
| Standards: | CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508IEC 60335-1 |
| Product certifications: | DNVCSACCCULGLLROS (Lloyds register of shipping)BVRINAGOSTUKCA |
| Connections - terminals: | Control circuit: lugs-ring terminals (external diameter: 8Â mm) Power circuit: lugs-ring terminals (external diameter: 8Â mm) |
| Tightening torque: | Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver flat Ø 8 mm M3.5Power circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Operating time: | 65.45...88.55 ms closing20...30 ms opening |
| Safety reliability level: | B10d = 1369863Â cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000Â cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability: | 30Â Mcycles |
| Maximum operating rate: | 3600 cyc/h 60 °C |
| Coil technology: | Built-in bidirectional peak limiting diode suppressor |
|---|---|
| Control circuit voltage limits: | 0.1...0.3 Uc (-40...70 °C):drop-out DC0.8...1.25 Uc (-40...60 °C):operational DC1...1.25 Uc (60...70 °C):operational DC |
| Time constant: | 40Â ms |
| Inrush power in W: | 2.4 W (at 20 °C) |
| Hold-in power consumption in W: | 2.4 W at 20 °C |
| Auxiliary contacts type: | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency: | 25...400 Hz |
| Minimum switching current: | 5Â mA for signalling circuit |
| Minimum switching voltage: | 17Â V for signalling circuit |
| Non-overlap time: | 1.5Â ms on de-energisation between NC and NO contact1.5Â ms on energisation between NC and NO contact |
| Insulation resistance: | > 10 MOhm for signalling circuit |
| Contact compatibility: | M5 |
| Compatibility code: | LC2D |