9,3/10 out of 1126 reviews
SCHNEIDER

variable speed drive ATV630 - 3kW - 380...480V - IP21/UL type 1 - ATV630U30N4

ATV630U30N4

€1,157.38 Excl. Tax
€1,388.86 Inc. Tax
available In stock – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa payplug fintecture alma
Technical informations
Range of product: Altivar Process ATV600
Product or component type: Variable speed drive
Product specific application: Process and utilities
Device short name: ATV630
Variant: Standard version
Product destination: Synchronous motorsAsynchronous motors
EMC filter: Integrated with 50 m conforming to EN/IEC 61800-3 category C2Integrated with 150 m conforming to EN/IEC 61800-3 category C3
IP degree of protection: IP21 conforming to IEC 61800-5-1IP21 conforming to IEC 60529
[Us] rated supply voltage: 380...480 V
Degree of protection: UL type 1 conforming to UL 508C
Type of cooling: Forced convection
Supply frequency: 50...60 Hz - 5...5 %
[Us] rated supply voltage: 380...480 V - 15...10 %
Motor power kW: 3 kW (normal duty)2.2 kW (heavy duty)
Motor power hp: 3 hp heavy duty
Line current: 5.8 A at 380 V (normal duty)5.1 A at 480 V (normal duty)4.5 A at 380 V (heavy duty)4 A at 480 V (heavy duty)
Prospective line Isc: 50 kA
Apparent power: 4.2 kVA at 480 V (normal duty)3.3 kVA at 480 V (heavy duty)
Continuous output current: 7.2 A at 4 kHz for normal duty5.6 A at 4 kHz for heavy duty
Maximum transient current: 8.4 A during 60 s (heavy duty)7.9 A during 60 s (normal duty)
Asynchronous motor control profile: Variable torque standardConstant torque standardOptimized torque mode
Synchronous motor control profile: Permanent magnet motorSynchronous reluctance motor
Speed drive output frequency: 0.1...500 Hz
Nominal switching frequency: 4 kHz
Switching frequency: 2...12 kHz adjustable4...12 kHz with derating factor
Safety function: STO (safe torque off) SIL 3
Discrete input logic: 16 preset speeds
Communication port protocol: EthernetModbus TCPModbus serial
Option card: Slot A: communication module, Profibus DP V1Slot A: communication module, ProfinetSlot A: communication module, DeviceNetSlot A: communication module, Modbus TCP/EtherNet/IPSlot A: communication module, CANopen daisy chain RJ45Slot A: communication module, CANopen SUB-D 9Slot A: communication module, CANopen screw terminalsSlot A/slot B: digital and analog I/O extension moduleSlot A/slot B: output relay extension moduleSlot A: communication module, Ethernet IP/Modbus TCP/MD-LinkCommunication module, BACnet MS/TPCommunication module, Ethernet Powerlink
Design of frequency changer: U converter
Network frequency: 50...60 Hz
Ambient air transport temperature: -40...70 °C
Relative symmetric mains voltage tolerance: 10 %
Maximum output voltage: 480.0 V
Relative symmetric network frequency tolerance: 5 %
Maximum acceleration under shock impact (during operation): 150 m/s² at 11 ms
Permitted relative humidity (during operation): Class 3K5 according to EN 60721-3
Maximum acceleration under vibrational stress (during operation): 10 m/s² at 13...200 Hz
Nominal output power: 3.0 W
4 quadrant operation possible: False
Permitted relative humidity (during transport): Class 2K5 according to EN 60721-3
Permitted relative humidity (during storage): Class 1K5 according to EN 60721-3
Capacity of DC link: 410.0 µF
Maximum deflection under vibratory load (during operation): 1.5 mm at 2...13 Hz
Operating element present: True
Number of HW interfaces serial TTY: 0
Power loss per device current dependent: 119.0 W
Power loss static current independent: 14.0 W
Number of output phases: 3
Maximum acceleration under vibratory load (during transport): 10 m/s² at 13...200 Hz
Number of input phases: 3
Number of inputs, potential-free: 0
Maximum deflection under vibratory load (during transport): 1.5 mm at 2...13 Hz
Brake chopper integrated: False
Maximum acceleration under shock load (during transport): 150 m/s² at 11 ms
Number of HW interfaces USB: 0
Number of HW interfaces other: 0
Optical interface present: False
Computer port: True
Supporting protocol for TCP/IP: True
Application in industrial area permitted: True
Application in domestic and commercial area permitted: False
Supporting protocol for PROFIBUS: True
Number of HW interfaces industrial Ethernet: 1
Number of inputs, bidirectional, not potential-free: 0
1 phase low current possible: False
Number of HW interfaces parallel: 0
Supporting protocol for KNX: False
Supporting protocol for ASI: False
Number of HW interfaces PROFINET: 0
Supporting protocol for CAN: True
Supporting protocol for INTERBUS: False
Supporting protocol for DeviceNet: False
Supporting protocol for SUCONET: False
Supporting protocol for LON: False
Supporting protocol for MODBUS: True
Supporting protocol for Data-Highway: False
Supporting protocol for PROFINET IO: True
Supporting protocol for PROFINET CBA: True
Maximum acceleration under shock load (during storage): 150 m/s² at 11 ms
Supporting protocol for Foundation Fieldbus: False
Supporting protocol for SERCOS: False
Maximum deflection under vibratory load (during storage): 1.5 mm at 2...13 Hz
Supporting protocol for DeviceNet Safety: False
Supporting protocol for INTERBUS-Safety: False
Supporting protocol for PROFIsafe: False
Supporting protocol for EtherNet/IP: True
Supporting protocol for AS-Interface Safety at Work: False
Maximum acceleration under vibratory load (during storage): 10 m/s² at 13...200 Hz
With safety function Safe torque off (STO): True
With sft fct Safe Stop 2 (SS2): False
With safety function Safe Stop 1 (SS1): False
Supporting protocol for SafetyBUS P: False
Supporting protocol for BACnet: False
Supporting protocol for other bus systems: False
Nominal output current: 7.2 A
With safety function Safe brake management (SBC/SBT): False
With safety function Safe Operating Stop (SOS): False
With safety function Safely Limited Position (SLP): False
With safety function Safely Limited Speed (SLS): False
With safety function Safe Speed Monitor (SSM): False
With safety function Safe Direction (SDI): False
Base load current at high overload: 5.6 A
Base load current at low overload: 7.2 A
Number of HW interfaces serial RS232: 0
With safety function Safe programmable logic: False
With safety function Safe Position (SP): False
EMC limit value (complied): True
Environmental class (during transport): Class 2C3 according to EN 60721-3-2Class 2S1 according to EN 60721-3-2
Environmental class (during operation): Class 3C3 according to IEC 60721-3-3Class 3S3 according to IEC 60721-3-3
Environmental class (during storage): Class 1C3 according to EN 60721-3-1Class 1S2 according to EN 60721-3-1
Number of HW interfaces serial RS422: 0
Number of HW interfaces serial RS485: 1
Mounting mode: Wall mount
Network number of phases: 3 phases
Discrete output number: 0
Discrete output type: Relay outputs R1A, R1B, R1C 250 V AC 3000 mARelay outputs R1A, R1B, R1C 30 V DC 3000 mARelay outputs R2A, R2C 250 V AC 5000 mARelay outputs R2A, R2C 30 V DC 5000 mARelay outputs R3A, R3C 250 V AC 5000 mARelay outputs R3A, R3C 30 V DC 5000 mA
Output voltage:
Permissible temporary current boost: 1.1 x In during 60 s (normal duty)1.5 x In during 60 s (heavy duty)
Motor slip compensation: Can be suppressedNot available in permanent magnet motor lawAdjustableAutomatic whatever the load
Acceleration and deceleration ramps: Linear adjustable separately from 0.01...9999 s
Physical interface: Ethernet2-wire RS 485
Braking to standstill: By DC injection
Protection type: Thermal protection: motorSafe torque off: motorMotor phase break: motorThermal protection: driveSafe torque off: driveOverheating: driveOvercurrent between output phases and earth: driveOverload of output voltage: driveShort-circuit protection: driveMotor phase break: driveOvervoltages on the DC bus: driveLine supply overvoltage: driveLine supply undervoltage: driveLine supply phase loss: driveOverspeed: driveBreak on the control circuit: drive
Transmission rate: 10, 100 Mbits4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Frequency resolution: Display unit: 0.1 HzAnalog input: 0.012/50 Hz
Transmission frame: RTU
Electrical connection: Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16Motor: screw terminal 2.5...6 mm²/AWG 14...AWG 10Line side: screw terminal 2.5...6 mm²/AWG 14...AWG 10
Connector type: RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCPRJ45 (on the remote graphic terminal) for Modbus serial
Data format: 8 bits, configurable odd, even or no parity
Type of polarization: No impedance
Exchange mode: Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses: 1...247 for Modbus serial
Method of access: Slave Modbus TCP
Supply: External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V),
Local signalling: 3 LEDs for local diagnostic3 LEDs (dual colour) for embedded communication status4 LEDs (dual colour) for communication module status1 LED (red) for presence of voltage
Width: 144 mm
Height: 350 mm
Depth: 203 mm
Product weight: 4.6 kg
Analogue input number: 3
Analogue input type: AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bitsAI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Discrete input number: 8
Discrete input type: DI7, DI8 programmable as pulse input: 0...30 kHz, 24 V DC (
Input compatibility: DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logic: Positive logic (source) (DI1...DI8), 11 V (state 1)Negative logic (sink) (DI1...DI8), > 16 V (state 0),
Analogue output number: 2
Analogue output type: Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bitsSoftware-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bitsSoftware-configurable current DQ-, DQ+: 30 V DCSoftware-configurable current DQ-, DQ+: 100 mA
Sampling duration: 2 ms +/- 0.5 ms (DI1...DI4) - discrete input5 ms +/- 1 ms (DI5, DI6) - discrete input5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input10 ms +/- 1 ms (AO1) - analog output
Accuracy: +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity error: AI1, AI2, AI3: +/- 0.15 % of maximum value for analog inputAO1, AO2: +/- 0.2 % for analog output
Relay output number: 3
Relay output type: Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh time: Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current: Relay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching current: Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Isolation: Between power and control terminals
Maximum output frequency: 500 kHz
Maximum associated fuse rating: 12.0 A
Maximum input current: 5.8 A
Specific application: Utility
IP degree of protection: IP21
Discrete and process manufacturing: Building - HVAC Compressor centrifugalFood and beverage processing Other applicationMining mineral and metal FanMining mineral and metal PumpOil and gas FanWater and waste water Other applicationBuilding - HVAC Screw compressorFood and beverage processing PumpFood and beverage processing FanFood and beverage processing AtomizationOil and gas Electro submersible pump (ESP)Oil and gas Water injection pumpOil and gas Jet fuel pumpOil and gas Compressor for refineryWater and waste water Centrifuge pumpWater and waste water Positive displacement pumpWater and waste water Electro submersible pump (ESP)Water and waste water Screw pumpWater and waste water Lobe compressorWater and waste water Screw compressorWater and waste water Compressor centrifugalWater and waste water FanWater and waste water ConveyorWater and waste water Mixer
Power range: 2.2...3 kW at 380...440 V 3 phases2.2...3 kW at 480...500 V 3 phases
Motor starter type: Variable speed drive
Housing material: Plastic
Quantity per set: 1
Enclosure mounting: Wall mounted
In short
Reference ATV630U30N4
Product Name variable speed drive ATV630 - 3kW - 380...480V - IP21/UL type 1 - ATV630U30N4
Related Categories