LC1D09P7 - SCHNEIDER

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 230 V AC coil - LC1D09P7

€24.61 €20.51
In stock – More than 100
Main features
  • range of product : TeSys DTeSys Deca
  • range : TeSysTeSys Deca
  • product name : TeSys DTeSys Deca
  • product or component type : Contactor
  • device short name : LC1D
  • contactor application : Resistive loadMotor control
  • utilisation category : AC-4AC-1AC-3
  • poles description : 3P
  • pole contact composition : 3 NO
  • [Ue] rated operational voltage : Power circuit: Power circuit:
  • [Ie] rated operational current : 9 A (at 25 A (at
  • motor power kW : 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)4 kW at 380...400 V AC 50/60 Hz (AC-3)4 kW at 415...440 V AC 50/60 Hz (AC-3)5.5 kW at 500 V AC 50/60 Hz (AC-3)5.5 kW at 660...690 V AC 50/60 Hz (AC-3)2.2 kW at 400 V AC 50/60 Hz (AC-4)
  • motor power hp : 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors2 hp at 200/208 V AC 50/60 Hz for 3 phases motors2 hp at 230/240 V AC 50/60 Hz for 3 phases motors5 hp at 460/480 V AC 50/60 Hz for 3 phases motors7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
  • control circuit type : AC at 50/60 Hz
  • [Uc] control circuit voltage : 230 V AC 50/60 Hz
  • auxiliary contact composition : 1 NO + 1 NC
  • [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947
  • overvoltage category : III
  • [Ith] conventional free air thermal current : 25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
  • Irms rated making capacity : 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
  • rated breaking capacity : 250 A at 440 V for power circuit conforming to IEC 60947
  • [Icw] rated short-time withstand current : 105 A 40 °C - 10 s for power circuit210 A 40 °C - 1 s for power circuit30 A 40 °C - 10 min for power circuit61 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuit
  • associated fuse rating : 10 A gG for signalling circuit conforming to IEC 60947-5-125 A gG at 20 A gG at
  • average impedance : 2.5 mOhm - Ith 25 A 50 Hz for power circuit
  • [Ui] rated insulation voltage : Power circuit: 690 V conforming to IEC 60947-4-1Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedSignalling circuit: 690 V conforming to IEC 60947-1Signalling circuit: 600 V CSA certifiedSignalling circuit: 600 V UL certified
  • electrical durability : 0.6 Mcycles 25 A AC-1 at Ue 2 Mcycles 9 A AC-3 at Ue
  • power dissipation per pole : 1.56 W AC-10.2 W AC-3
  • protective cover : With
  • mounting support : RailPlate
  • standards : CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508IEC 60335-1
  • product certifications : GOSTBVLROS (Lloyds register of shipping)DNVCSARINACCCULGLUKCA
  • connections - terminals : Power circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endPower circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endPower circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable end
  • tightening torque : Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmPower circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
  • operating time : 12...22 ms closing4...19 ms opening
  • safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
  • mechanical durability : 15 Mcycles
  • maximum operating rate : 3600 cyc/h 60 °C
Details
  • coil technology : Without built-in suppressor module
  • control circuit voltage limits : 0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.1 Uc (-40...60 °C):operational AC 50 Hz0.85...1.1 Uc (-40...60 °C):operational AC 60 Hz1...1.1 Uc (60...70 °C):operational AC 50/60 Hz
  • inrush power in VA : 70 VA 60 Hz cos phi 0.75 (at 20 °C)70 VA 50 Hz cos phi 0.75 (at 20 °C)
  • hold-in power consumption in VA : 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7 VA 50 Hz cos phi 0.3 (at 20 °C)
  • heat dissipation : 2...3 W at 50/60 Hz
  • auxiliary contacts type : type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
  • signalling circuit frequency : 25...400 Hz
  • minimum switching current : 5 mA for signalling circuit
  • minimum switching voltage : 17 V for signalling circuit
  • non-overlap time : 1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contact
  • insulation resistance : > 10 MOhm for signalling circuit
  • contact compatibility : M2
  • compatibility code : LC1D
  • power range : 1.1...2 kW at 200...240 V 3 phases2.2...3 kW at 380...440 V 3 phases4...6 kW at 380...440 V 3 phases4...6 kW at 480...500 V 3 phases
  • motor starter type : Direct on-line contactor
  • contactor coil voltage : 230 V AC standard
Additional information
  • IP degree of protection : IP20 front face conforming to IEC 60529
  • protective treatment : TH conforming to IEC 60068-2-30
  • pollution degree : 3
  • ambient air temperature for operation : -40...60 °C60...70 °C with derating
  • ambient air temperature for storage : -60...80 °C
  • operating altitude : 0...3000 m
  • fire resistance : 850 °C conforming to IEC 60695-2-1
  • flame retardance : V1 conforming to UL 94
  • mechanical robustness : Vibrations contactor open: 2 Gn, 5...300 HzVibrations contactor closed: 4 Gn, 5...300 HzShocks contactor open: 10 Gn for 11 msShocks contactor closed: 15 Gn for 11 ms
  • height : 77 mm
  • width : 45 mm
  • depth : 86 mm
  • product weight : 0.32 kg
  • REACh Regulation : Free of Substances of Very High Concern above the thresholdREACh free of SVHC
More Information
  • Code EAN : 3389110348903
LC1D09P7

LC1D09P7 - SCHNEIDER

TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 230 V AC coil - LC1D09P7
€24.61 €20.51

Additional discounts

on important order

Fast delivery

when products are in stock

Satisfied or refunded

14 days to make your choice :)

Secure payment

to guarantee the security of your transactions