Technical informations
Range of product: NSX100...250NSX400...630MasterPact NTCompact NS100...630Compact NS630b...1600MasterPact NW
Product or component type: Interface and control unit
Accessory / separate part category: Interlocking accessory
Range compatibility: ComPact NS circuit breakerComPact NSX circuit breakerMasterPact NT circuit breakerMasterPact NW circuit breaker
Device short name: ACP + UA
[Us] rated supply voltage: 380...415 V AC at 50/60 Hz440 V AC at 60 Hz
Operating mode: Forced operation on replacement sourceStop (both normal and replacement source off)Automatic operationForced operation on normal source
Interlocked device: MasterPact NWNSX400...630NSX100...250Compact NS100...630MasterPact NTCompact NS630b...1600
Selection modes: Circuit breaker on RCircuit breaker on N
Test function: By pressing the test button on the front of the controller
Complementary function: Additional contact: transfer to replacement source only if contact is closedSetting of maximum startup time for the replacement sourceForced normal source if replacement source not operational during peak-tariffSelection of type of normal source (single-phase or three-phase)Voluntary transfer to replacement source (e.g. energy management commands)
Local signalling: OffFault tripOn
Input type: Contacts customer voluntary order to transfer to source R
Output type: Contacts customer: indication of operation in automatic or stop mode
[Ith] conventional free air thermal current: 8 A
[Ie] rated operational current: AC-12: 4 A AC 440 VAC-12: 5 A AC 380/415 VAC-12: 8 A AC 110 VAC-12: 8 A AC 220/240 VAC-12: 8 A AC 24 VAC-12: 8 A AC 48 VAC-13: 6 A AC 110 VAC-13: 6 A AC 220/240 VAC-13: 7 A AC 24 VAC-13: 7 A AC 48 VAC-14: 4 A AC 110 VAC-14: 4 A AC 220/240 VAC-14: 5 A AC 24 VAC-14: 5 A AC 48 VAC-15: 3 A AC 220/240 VAC-15: 4 A AC 110 VAC-15: 5 A AC 24 VAC-15: 5 A AC 48 VDC-12: 0.4 A DC 250 VDC-12: 0.6 A DC 110 VDC-12: 2 A DC 48 VDC-12: 8 A DC 24 VDC-13: 2 A 24 V