Technical informations
Range: Masterpact
Product name: Masterpact MTZ2
Device short name: MTZ2 25 H1
Product or component type: Circuit breaker
Device application: Protection
Circuit breaker name: Masterpact MTZ2 25
Poles description: 4P
Neutral position: Left
Network type: AC
Network frequency: 50/60 Hz
Breaking capacity code: H1
Suitability for isolation: Yes conforming to IEC 60947-2
Utilisation category: Category B
Control type: Push-button
Mounting mode: Fixed
Mounting support: Base plateRails
[In] rated current: 2500 A at 40 °C
[Ui] rated insulation voltage: 1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 12 kV conforming to IEC 60947-2
[Icm] rated short-circuit making capacity: 145 kA 220/415 V AC at 50/60 Hz145 kA 440 V AC at 50/60 Hz145 kA 500/525 V AC at 50/60 Hz145 kA 660/690 V AC at 50/60 Hz
[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
Circuit breaker CT rating: 2500 A
Breaking capacity: 66 kA Icu at 220/415 V AC 50/60 Hz conforming to IEC 60947-266 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-266 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-266 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity: 66 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-266 kA at 440 V AC 50/60 Hz conforming to IEC 60947-266 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-266 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability: 20000 cycles with periodic preventive maintenance conforming to IEC 60947-2
Electrical durability: AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to IEC 60947-32500 cycles 690 V AC 50/60 Hz conforming to IEC 60947-25000 cycles 440 V AC 50/60 Hz conforming to IEC 60947-2AC-23A: 2500 cycles 690 V AC 50/60 Hz conforming to IEC 60947-3AC-23A: 5000 cycles 440 V AC 50/60 Hz conforming to IEC 60947-3
Connection pitch: 115 mm
[Icw] rated short-time withstand current: 66 kA 0.5 s conforming to IEC 60947-266 kA 1 s conforming to IEC 60947-266 kA 3 s conforming to IEC 60947-2
Maximum breaking time: 25 ms
Maximum closing response time: 70 ms
Height: 352 mm
Width: 537 mm
Depth: 300 mm
Compatibility code: NW25