SCHNEIDER
circuit breaker basic frame, Masterpact MTZ2 25H1, 2500 A, 66 kA at 440 VAC 50/60 Hz, 4 poles, fixed, without Micrologic - LV848076
LV848076
€9,433.06 Excl. Tax
€11,319.67 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 100€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | Masterpact |
---|---|
Product name: | Masterpact MTZ2 |
Device short name: | MTZ2 25 H1 |
Product or component type: | Circuit breaker |
Device application: | Protection |
Circuit breaker name: | Masterpact MTZ2 25 |
Poles description: | 4P |
Neutral position: | Left |
Network type: | AC |
Network frequency: | 50/60 Hz |
Breaking capacity code: | H1 |
Suitability for isolation: | Yes conforming to IEC 60947-2 |
Utilisation category: | Category B |
Control type: | Push-button |
---|---|
Mounting mode: | Fixed |
Mounting support: | Base plateRails |
[In] rated current: | 2500 A at 40 °C |
[Ui] rated insulation voltage: | 1000 V AC 50/60 Hz conforming to IEC 60947-2 |
[Uimp] rated impulse withstand voltage: | 12 kV conforming to IEC 60947-2 |
[Icm] rated short-circuit making capacity: | 145 kA 220/415 V AC at 50/60 Hz145 kA 440 V AC at 50/60 Hz145 kA 500/525 V AC at 50/60 Hz145 kA 660/690 V AC at 50/60 Hz |
[Ue] rated operational voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Circuit breaker CT rating: | 2500 A |
Breaking capacity: | 66 kA Icu at 220/415 V AC 50/60 Hz conforming to IEC 60947-266 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-266 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-266 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ics] rated service breaking capacity: | 66 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-266 kA at 440 V AC 50/60 Hz conforming to IEC 60947-266 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-266 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
Mechanical durability: | 20000 cycles with periodic preventive maintenance conforming to IEC 60947-2 |
Electrical durability: | AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to IEC 60947-32500 cycles 690 V AC 50/60 Hz conforming to IEC 60947-25000 cycles 440 V AC 50/60 Hz conforming to IEC 60947-2AC-23A: 2500 cycles 690 V AC 50/60 Hz conforming to IEC 60947-3AC-23A: 5000 cycles 440 V AC 50/60 Hz conforming to IEC 60947-3 |
Connection pitch: | 115 mm |
[Icw] rated short-time withstand current: | 66 kA 0.5 s conforming to IEC 60947-266 kA 1 s conforming to IEC 60947-266 kA 3 s conforming to IEC 60947-2 |
Maximum breaking time: | 25 ms |
Maximum closing response time: | 70 ms |
Height: | 352 mm |
Width: | 537 mm |
Depth: | 300 mm |
Compatibility code: | NW25 |
In short
Reference LV848076
Product Name circuit breaker basic frame, Masterpact MTZ2 25H1, 2500 A, 66 kA at 440 VAC 50/60 Hz, 4 poles, fixed, without Micrologic - LV848076
Related Categories