SCHNEIDER
Circuit breaker Masterpact MTZ2 32H2, 3200 A, 3P drawout, without Micrologic - LV848313
LV848313
€10,893.88 Excl. Tax
€13,072.66 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process – Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 100€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range: | Masterpact |
---|---|
Product name: | Masterpact MTZ2 |
Device short name: | MTZ2 32 H2 |
Product or component type: | Circuit breaker |
Device application: | Protection |
Circuit breaker name: | Masterpact MTZ2 32 |
Poles description: | 3P |
Network type: | AC |
Network frequency: | 50/60 Hz |
Breaking capacity code: | H2 |
Suitability for isolation: | Yes conforming to IEC 60947-2 |
Utilisation category: | Category B |
Control type: | Push-button |
---|---|
Mounting mode: | Drawout |
Mounting support: | RailsBase plate |
[In] rated current: | 3200 A at 40 °C |
[Ui] rated insulation voltage: | 1000 V AC 50/60 Hz conforming to IEC 60947-2 |
[Uimp] rated impulse withstand voltage: | 12 kV conforming to IEC 60947-2 |
[Icm] rated short-circuit making capacity: | 220 kA 220/415 V AC at 50/60 Hz220 kA 440 V AC at 50/60 Hz187 kA 500/525 V AC at 50/60 Hz187 kA 660/690 V AC at 50/60 Hz |
[Ue] rated operational voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
Circuit breaker CT rating: | 3200 A |
Breaking capacity: | 100 kA Icu at 220/415 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ics] rated service breaking capacity: | 100 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2100 kA at 440 V AC 50/60 Hz conforming to IEC 60947-285 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-285 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
Mechanical durability: | 20000 cycles with periodic preventive maintenance conforming to IEC 60947-2 |
Electrical durability: | AC-3: 6000 cycles 440/690 V AC 50/60 Hz conforming to IEC 60947-32500 cycles 690 V AC 50/60 Hz conforming to IEC 60947-25000 cycles 440 V AC 50/60 Hz conforming to IEC 60947-2AC-23A: 2500 cycles 690 V AC 50/60 Hz conforming to IEC 60947-3AC-23A: 5000 cycles 440 V AC 50/60 Hz conforming to IEC 60947-3 |
Connection pitch: | 115 mm |
[Icw] rated short-time withstand current: | 85 kA 0.5 s conforming to IEC 60947-285 kA 1 s conforming to IEC 60947-275 kA 3 s conforming to IEC 60947-2 |
Integral instant protection: | 171...209 kA |
Maximum breaking time: | 25 ms |
Maximum closing response time: | 70 ms |
Height: | Drawout circuit breaker without chassis: 300 mmDrawout circuit breaker with chassis: 439 mm |
Width: | Drawout circuit breaker without chassis: 378 mmDrawout circuit breaker with chassis: 441 mm |
Depth: | Drawout circuit breaker without chassis: 300 mmDrawout circuit breaker with chassis: 403 mm |
Compatibility code: | NW32 |