Technical informations
Range of product: Harmony Safety Automation
Product or component type: Safety module
Safety module name: XPSUAT
Safety module application: Monitoring antivalent contactsFor emergency stop, guard and light curtain monitoringMonitoring of pressure-sensitive 4-wire protective devices
Function of module: Emergency stop button with 2 NC contactsGuard monitoring with 1 or 2 limit switchesMonitoring 2 PNP sensorsMagnetic switch monitoringLight curtain monitoringRFID switchMonitoring of electro-sensitive protection equipment (ESPE)Sensing mat/edgesProximity sensor monitoringMonitoring 1 PNP + 1 NPN sensor
Safety level: Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1Can reach SILCL 3 for normally open relay contact conforming to IEC 62061Can reach SIL 3 for normally open relay contact conforming to IEC 61508Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061Can reach SIL 1 for normally closed relay contact conforming to IEC 61508
Safety reliability data: MTTFd > 30 years conforming to ISO 13849-1Dcavg >= 99 % conforming to ISO 13849-1PFHd = 0.94E-09 conforming to ISO 13849-1 for SS0PFHd = 0.95E-09 conforming to ISO 13849-1 for SS1HFT = 1 conforming to IEC 62061PFHd = 0.94E-09 conforming to IEC 62061 for SS0PFHd = 0.95E-09 conforming to IEC 62061 for SS1SFF > 99% conforming to IEC 62061HFT = 1 conforming to IEC 61508-1PFHd = 0.94E-09 conforming to IEC 61508-1 for SS0PFHd = 0.95E-09 conforming to IEC 61508-1 for SS1SFF > 99% conforming to IEC 61508-1Type = B conforming to IEC 61508-1
Electrical circuit type: NC pairPNP pairAntivalent pairOSSD pair
Connections - terminals: Removable screw terminal block, 0.2...2.5 mm² solid or flexibleRemovable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductorRemovable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductorRemovable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezelRemovable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
[Us] rated supply voltage: 24 V AC - 15...10 %24 V DC - 20...20 %
Synchronisation time between inputs: 0.5 s2 s4 s
Type of start: Automatic/manual/monitored
Power consumption in W: 3 W 24 V DC
Power consumption in VA: 6.5 VA 24 V AC 50/60 Hz
Input protection type: Internal, electronic
Auxiliary contact composition: 1 NC configurable3 NO configurable3 NO immediate
Number of inputs: 2 positive safety input 24 V DC 8 mA1 negative safety input
Maximum line resistance: 500 Ohm
Time delay range: 0...900 s
Input compatibility: Normally closed circuit conforming to ISO 14119XC limit switch conforming to ISO 14119Mechanical contact conforming to ISO 14119Normally closed circuit conforming to ISO 13850Antivalent pair conforming to ISO 14119OSSD pair conforming to IEC 61496-1-23-wire proximity sensors PNP
[Ie] rated operational current: 5 A AC-1 for normally open relay contact3 A AC-15 for normally open relay contact5 A DC-1 for normally open relay contact3 A DC-13 for normally open relay contact3 A AC-1 for normally closed relay contact1 A AC-15 for normally closed relay contact3 A DC-1 for normally closed relay contact1 A DC-13 for normally closed relay contact
Number of outputs: 4 on/off configurable pulsed output
Input/output type: Semiconductor output 24 V DC, 20 mA Z2, not safety-relatedPulsed output for diagnostics 24 V DC, 20 mA Z1, not safety-related
[Ith] conventional free air thermal current: 16 A
Associated fuse rating: 10 A gG for NO relay output circuit conforming to IEC 60947-1
Minimum output current: 20 mA for relay output
Minimum output voltage: 24 V for relay output
Maximum response time on input open: 20 ms
[Ui] rated insulation voltage: 250 V (pollution degree 2) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage: 4 kV overvoltage category II conforming to EN/IEC 60947-1
Mounting support: 35 mm symmetrical DIN rail
Depth: 120 mm
Height: 100 mm
Width: 45 mm
Product weight: 0.350 kg