Range of product: OsiSense ATEX D
Series name: Special format
Product or component type: Limit switch
Product specific application: For conveyor belt shift monitoring
Device short name: XCR
Body type: Fixed
Head type: Rotary head
Material: Metal
Fixing mode: By the body
Movement of operating head: Rotary
Type of operator: Spring return roller zinc plated steel with lever
Switch actuation: By conveyor belt
Type of approach: Lateral approach, 2 directions
Electrical connection: Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Cable entry number: 1 tapped entry for Pg 13.5 cable gland (included) 9...12 mm
Number of poles: 2
Contacts type and composition: 2 x 1 C/O
Contacts insulation form: Za
Contact operation: Snap action
Number of steps: 2
Contact block per direction [control circuit]: 1 per direction
Positive opening: With
Minimum torque for tripping: 1 N.m
Maximum actuation speed: 1.5 m/s
IP degree of protection: IP65 conforming to IEC 60529
Body material: Zinc alloy
Minimum actuation speed: 0.01 m/min
Tripping angle: 10 ° for fault signalling18 ° for stopping of the conveyor belt
Maximum displacement angle: -90 °90 °
Contact code designation: A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN 60947-5-1A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to IEC 60947-5-1 appendix AQ300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ui] rated insulation voltage: 300 V conforming to UL 508500 V conforming to NF C 20-040 group C500 V (pollution degree 3) conforming to IEC 60947-1500 V (pollution degree 3) conforming to VDE 0110
Maximum resistance across terminals: 25 MOhm conforming to IEC 60255-7 category 325 MOhm conforming to NF C 93-050 method A
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 606646 kV conforming to IEC 60947-1
Short-circuit protection: 10 A cartridge fuse, type gG
Electrical durability: 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate
Mechanical durability: 300000 cycles
Marking: II2 D-Ex tb IIIC T85°C Db IP66/67
Width: 85 mm
Height: 95 mm
Depth: 75 mm
Compatibility code: XCR