calcActive())">
SCHNEIDER
TeSys Integral - contactor breaker - 63 A AC-43 - 48 V DC coil - LD1LD030ED
LD1LD030ED
This product is no longer available. Contact us for a suitable replacement solution tailored to your needs.
Technical informations
| Range of product: | Integral 63 |
|---|---|
| Range: | TeSys |
| Product name: | TeSys Integral 63 |
| Product or component type: | Contactor breaker |
| Device short name: | LD1LD |
| Utilisation category: | AC-43 |
|---|---|
| Poles description: | 3P |
| [Ue] rated operational voltage: | 690 V AC 50/60 Hz |
| [Ie] rated operational current: | 63Â A AC AC-43 |
| [Ith] conventional free air thermal current: | 63 A (at 40 °C) |
| Motor power kW: | 15Â kW at 220...240 V AC 50/60 Hz30Â kW at 400 V AC 50/60 Hz33Â kW at 415 V AC 50/60 Hz37Â kW at 500 V AC 50/60 Hz55Â kW at 660 V AC 50/60 Hz33Â kW at 440 V AC 50/60 Hz |
| [Uc] control circuit voltage: | 48 V DC |
| Control type: | Knob black front |
| Irms rated making capacity: | 756Â A conforming to IEC 60947-4946Â A conforming to IEC 60947-4 |
| [Ipk] rated peak withstand current: | 105Â kA conforming to IEC 60947-2 |
| Breaking capacity: | Icu 10Â kA at 600...690 V (cos ? 0.5) conforming to IEC 60947-2Icu 30Â kA at 480...525 V (cos ? 0.25) conforming to IEC 60947-6-2Icu 50Â kA at |
| [Ics] rated service breaking capacity: | 10Â kA at 600...690 V conforming to IEC 60947-235Â kA at 480...525 V conforming to IEC 60947-250Â kA at |
| Maximum breaking time: | 4Â ms |
| Thermal stress limit: | 300000 A².s |
| [Uimp] rated impulse withstand voltage: | 8Â kV conforming to IEC 60947-4 |
| Control circuit voltage limits: | 0.25...0.7 Uc drop-out 55 °C0.85...1.1 Uc operation 55 °C |
| [Ui] rated insulation voltage: | 690Â V conforming to IEC 60947-1 |
| Inrush power in W: | 300 W (at 20 °C) |
| Hold-in power consumption in W: | 8 W at 20 °C |
| Heat dissipation: | 5Â W at 32Â A per pole, hot state for power circuit7Â W at 50Â A per pole, hot state for power circuit9Â W at 63Â A per pole, hot state for power circuit4.4Â W at 25Â A per pole, hot state for power circuit5.8Â W at 40Â A per pole, hot state for power circuit |
| Operating time: | 15...25 ms DC network opening at 20 °C for control circuit25...40 ms DC network closing at 20 °C for control circuit |
| Electrical durability: | 1Â Mcycles on AC-3 3Â kA at 415 V - after 1 cycle O-CO-r-CO at Isc0.9Â Mcycles on AC-3 10Â kA at 415 V - after 1 cycle O-CO-r-CO at Isc0.6Â Mcycles on AC-3 25Â kA at 415 V - after 1 cycle O-CO-r-CO at Isc0.5Â Mcycles on AC-3 35Â kA at 415 V - after 1 cycle O-CO-r-CO at Isc0.2Â Mcycles on AC-3 50Â kA at 415 V - after 1 cycle O-CO-r-CO at Isc |
| Mechanical durability: | 1.2Â Mcycles |
| Connections - terminals: | Power circuit: screw clamp terminals 1 cable(s) 6...50 mm² - flexible - without cable endPower circuit: screw clamp terminals 2 cable(s) 6...25 mm² - flexible - without cable endPower circuit: screw clamp terminals 1 cable(s) 6...25 mm² - flexible - with cable endPower circuit: screw clamp terminals 2 cable(s) 6...25 mm² - flexible - with cable endPower circuit: screw clamp terminals 1 cable(s) 6...50 mm² - solid |
| Tightening torque: | Power circuit: 6Â N.m - on screw clamp terminals |
| Width: | 90Â mm |
| Height: | 243Â mm |
| Depth: | 192Â mm |
| Product weight: | 3.7Â kg |
| Compatibility code: | LD1LD |
In short
Reference LD1LD030ED
Product Name TeSys Integral - contactor breaker - 63 A AC-43 - 48 V DC coil - LD1LD030ED
Range TeSys