9,3/10 out of 1126 reviews
SCHNEIDER

standard analog input kit STB - 2 I - 15 bits + sign - STBART0200K

STBART0200K

€324.06 Excl. Tax
€388.87 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa payplug fintecture alma
Technical informations
Range of product: Modicon STB distributed I/O solution
Product or component type: Standard analog input kit
Kit composition: STBART0200 moduleSTBXTS1100, 6-terminal screw type connectorSTBXBA1000 baseSTBXTS2100, 6-terminal spring clamp connector
Analogue input type: Voltage +/- 80 mVTemperature probe -100...+260 °C Cu 10 2, 3 or 4 wires IECTemperature probe -100...+450 °C Pt 100 2, 3 or 4 wires US/JISTemperature probe -100...+450 °C Pt 1000 2, 3 or 4 wires US/JISTemperature probe -200...+850 °C Pt 100 2, 3 or 4 wires IECTemperature probe -200...+850 °C Pt 1000 2, 3 or 4 wires IECTemperature probe -60...+180 °C Ni 100 2, 3 or 4 wires IECTemperature probe -60...+180 °C Ni 1000 2, 3 or 4 wires IECThermocouple +130...+1820 °C thermocouple BThermocouple -200...+760 °C thermocouple JThermocouple -270...+1000 °C thermocouple EThermocouple -270...+1370 °C thermocouple KThermocouple -270...+400 °C thermocouple TThermocouple -50...+1665 °C thermocouple RThermocouple -50...+1665 °C thermocouple S
Analogue input number: 2
Analogue input resolution: 15 bits + sign
Type of filter: Single low pass input filter 25 Hz
Absolute maximum input: +/- 7.5 V DC
Cold swapping: Yes
Hot swapping fallback: Yes for standard NIMs
Fallback status: State 0 basic NIMsUser configurable standard NIMs
Data format: EN 61131-2IEC 61131-2
Input impedance: 10 MOhm +/- 80 mV
Maximum supply current for sensors: 100 mA per input channels
Protection type: Short-circuit protection
Absolute accuracy error: +/- 0.1 % of full scale 25 °C internal+/- 0.15 % of full scale 25 °C external
Insulation between channels and logic bus: 1500 V for 1 minute
Addressing requirement: 1 word for cold-junction compensation2 input words
Product compatibility: Mounting base STBXBA1000Power distribution module STBPDT3100/3105
[Us] rated supply voltage: 24 V DC
Supply: Power distribution module
Current consumption: 30 mA at 5 V DC for logic bus
Measurement resolution: 0.01 mV voltage0.1 °C or 0.1 °F temperature probe0.1 °C or 0.1 °F thermocouple
Conversion time: 150 ms voltage 60 Hz170 ms voltage 50 Hz180 ms temperature probe 60 Hz 2 or 4 wires200 ms temperature probe 50 Hz 2 or 4 wires210 ms thermocouple with internal cold-junction compensation 60 Hz230 ms thermocouple with internal cold-junction compensation 50 Hz300 ms temperature probe 60 Hz 3 wires340 ms temperature probe 50 Hz 3 wires360 ms thermocouple with external cold-junction compensation 60 Hz400 ms thermocouple with external cold-junction compensation 50 Hz
Maximum wiring resistance: 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires50 Ohm Cu 10 IEC/US/JIS 4 wires50 Ohm Ni 100 IEC/US/JIS 4 wires50 Ohm Pt 100 IEC/US/JIS 4 wires500 Ohm Ni 1000 IEC/US/JIS 4 wires500 Ohm Pt 1000 IEC/US/JIS 4 wires
Measurement accuracy: +/- 1 °C Ni 100 25 °C external+/- 1 °C Ni 100 25 °C internal+/- 1 °C Ni 1000 25 °C external+/- 1 °C Ni 1000 25 °C internal+/- 1 °C Pt 100 25 °C internal+/- 1 °C Pt 1000 25 °C internal+/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C+/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C+/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C+/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C+/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C+/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C+/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C+/- 2 °C Pt 100 25 °C external+/- 2 °C Pt 1000 25 °C external+/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C+/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C+/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C+/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C+/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C+/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C+/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C+/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C+/- 4 °C Cu 10 25 °C external+/- 4 °C Cu 10 25 °C internal+/- 4 °C thermocouple K with internal cold-junction compensation 25 °C+/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C+/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C+/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C+/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C+/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C+/- 5 °C thermocouple S with internal cold-junction compensation 60 °C+/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C+/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C+/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C+/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C+/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C+/- 7 °C thermocouple J with internal cold-junction compensation 60 °C
Marking: CE
Overvoltage category: II
Status LED: 1 LED (green)module status (RDY)1 LED (red)module error (ERR)
In short
Reference STBART0200K
Product Name standard analog input kit STB - 2 I - 15 bits + sign - STBART0200K
Related Categories