9,3/10 out of 1126 reviews
SCHNEIDER

limit switch XCR - metal stay put T rods lever square rod 6 mm - 2X(1NC+NO) - XCRF17

XCRF17

€215.18 Excl. Tax
€258.22 Inc. Tax
available In stock more than 25 units – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa payplug fintecture alma
Technical informations
Range of product: OsiSense XC
Series name: Special format
Product or component type: Limit switch
Product specific application: For hoisting and mechanical handling applications
Device short name: XCR
Sensor design: -
Body type: Fixed
Head type: Rotary head
Material: Metal
Fixing mode: By the body
Movement of operating head: Rotary
Type of operator: Stay put crossed rods lever metal square rod 6 mm
Type of approach: Lateral approach, 2 directions
Electrical connection: Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Number of poles: 4
Contacts type and composition: 2 x (1 NC + 1 NO)
Contact operation: Snap action
Contact block per direction [control circuit]: 1 per direction
Positive opening: With
Body material: Zinc alloy
Switch actuation: By any moving part
Cable entry: 1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9...12 mm conforming to NF C 68-300
Contacts insulation form: Zb
Number of steps: 1
Positive opening minimum torque: 0.7 N.m
Minimum torque for tripping: 0.6 N.m
Minimum actuation speed: 0.01 m/min
Maximum actuation speed: 1.5 m/s
Maximum displacement angle: -90 °90 °
Contact code designation: A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix AQ300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage: 300 V conforming to UL 508500 V (pollution degree 3) conforming to IEC 60947-1500 V (pollution degree 3) conforming to VDE 0110300 V conforming to CSA C22.2 No 14
Maximum resistance across terminals: 25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 606646 kV conforming to IEC 60947-1
Short-circuit protection: 10 A cartridge fuse, type gG
Electrical durability: 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate
Mechanical durability: 10000000 cycles
Width: 85 mm
Height: 95 mm
Depth: 75 mm
Product weight: 1.135 kg
Terminals description ISO n°1: (13-14)NO(21-22)NC
Compatibility code: XCR
In short
Reference XCRF17
Product Name limit switch XCR - metal stay put T rods lever square rod 6 mm - 2X(1NC+NO) - XCRF17