Quick Overview - TeSys K - LC2K0901E7

  • Main
    • range of product : TeSys K
    • range : TeSys
    • product name : TeSys K
    • product or component type : Reversing contactor
    • device short name : LC2K
    • device application : Control
    • contactor application : Resistive load
      Motor control
    • utilisation category : AC-1
      AC-3
      AC-4
    • device presentation : Preassembled with reversing power busbar
    • poles description : 3P
    • pole contact composition : 3 NO
    • [Ue] rated operational voltage : 690 V AC 50/60 Hz for power circuit
      <= 690 V AC 50/60 Hz for signalling circuit
    • [Ie] rated operational current : 9 A at <= 440 V AC AC-3 for power circuit
      20 A (<= 50 °C) at <= 440 V AC AC-1 for power circuit
      16 A (<= 70 °C) at 690 V AC AC-1 for power circuit
    • motor power kW : 4 kW at 380...415 V AC 50/60 Hz
      4 kW at 440 V AC 50/60 Hz
      4 kW at 480 V AC 50/60 Hz
      4 kW at 500...600 V AC 50/60 Hz
      4 kW at 660...690 V AC 50/60 Hz
      2.2 kW at 220...230 V AC 50/60 Hz
    • control circuit type : AC 50/60 Hz
    • [Uc] control circuit voltage : 48 V AC 50/60 Hz
    • auxiliary contact composition : 1 NC
    • [Uimp] rated impulse withstand voltage : 8 kV
    • overvoltage category : III
    • [Ith] conventional free air thermal current : 20 A at <= 50 °C for power circuit
      10 A at <= 50 °C for signalling circuit
    • Irms rated making capacity : 110 A AC for power circuit conforming to NF C 63-110
      110 A AC for power circuit conforming to IEC 60947
      110 A AC for signalling circuit conforming to IEC 60947
    • rated breaking capacity : 110 A at 415 V conforming to IEC 60947
      110 A at 440 V conforming to IEC 60947
      80 A at 500 V conforming to IEC 60947
      110 A at 220...230 V conforming to IEC 60947
      110 A at 380...400 V conforming to IEC 60947
      70 A at 660...690 V conforming to IEC 60947
    • [Icw] rated short-time withstand current : 20 A <= 50 °C >= 15 min power circuit
      90 A <= 50 °C 1 s power circuit
      85 A <= 50 °C 5 s power circuit
      80 A <= 50 °C 10 s power circuit
      60 A <= 50 °C 30 s power circuit
      45 A <= 50 °C 1 min power circuit
      40 A <= 50 °C 3 min power circuit
      80 A 1 s signalling circuit
      90 A 500 ms signalling circuit
      110 A 100 ms signalling circuit
    • associated fuse rating : 25 A gG at <= 440 V for power circuit
      25 A aM for power circuit
      10 A gG for signalling circuit conforming to IEC 60947
      10 A gG for signalling circuit conforming to VDE 0660
    • average impedance : 3 mOhm at 50 Hz - Ith 20 A for power circuit
    • [Ui] rated insulation voltage : 690 V for signalling circuit conforming to IEC 60947-4-1
      690 V for signalling circuit conforming to IEC 60947-5-1
      600 V for signalling circuit conforming to UL 508
      600 V for power circuit conforming to CSA C22.2 No 14
      600 V for signalling circuit conforming to CSA C22.2 No 14
      690 V for power circuit conforming to IEC 60947-4-1
      600 V for power circuit conforming to UL 508
    • electrical durability : 0.18 Mcycles 20 A AC-1 at Ue <= 440 V
      1.3 Mcycles 9 A AC-3 at Ue <= 440 V
    • interlocking type : Mechanical
    • mounting support : Rail
      Plate
    • standards : BS 5424
      IEC 60947
      NF C 63-110
      VDE 0660
    • product certifications : CSA
      UL
    • connections - terminals : Screw clamp terminals 1 cable(s) 1.5...4 mm² - cable stiffness: solid
      Screw clamp terminals 1 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
      Screw clamp terminals 1 cable(s) 0.34...2.5 mm² - cable stiffness: flexible - with cable end
      Screw clamp terminals 2 cable(s) 1.5...4 mm² - cable stiffness: solid
      Screw clamp terminals 2 cable(s) 0.75...4 mm² - cable stiffness: flexible - without cable end
      Screw clamp terminals 2 cable(s) 0.34...1.5 mm² - cable stiffness: flexible - with cable end
    • tightening torque : 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2
      1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
    • operating time : 10...20 ms coil de-energisation and NO opening
      10...20 ms coil energisation and NO closing
    • safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
      B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    • mechanical durability : 5 Mcycles
    • operating rate : 3600 cyc/h

Details - Reversing contactor - LC2K

  • Complementary
    • control circuit voltage limits : 0.2...0.75 Uc at <= 50 °C drop-out
      0.8...1.15 Uc at <= 50 °C operational
    • inrush power in VA : 30 VA at 20 °C
    • hold-in power consumption in VA : 4.5 VA at 20 °C
    • heat dissipation : 1.3 W
    • auxiliary contacts type : Type instantaneous 1 NC
    • signalling circuit frequency : <= 400 Hz
    • minimum switching current : 5 mA for signalling circuit
    • minimum switching voltage : 17 V for signalling circuit
    • non overlap distance : 0.5 mm
    • insulation resistance : > 10 MOhm for signalling circuit

Additional Information - LC2K - TeSys - LC2K0901E7

Manufacturer Schneider
Code EAN 3389110491876
Plus d'infos
  • Environment
    • IP degree of protection : IP20 conforming to VDE 0106
    • protective treatment : TC conforming to IEC 60068
      TC conforming to DIN 50016
    • ambient air temperature for operation : -25...50 °C
    • ambient air temperature for storage : -50...80 °C
    • operating altitude : 2000 m without derating derating in temperature
    • flame retardance : V1 conforming to UL 94
      Requirement 2 conforming to NF F 16-101
      Requirement 2 conforming to NF F 16-102
    • mechanical robustness : Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27
      Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27
      Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27
      Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27
      Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27
      Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27
      Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6
      Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
    • height : 58 mm
    • width : 90 mm
    • depth : 57 mm
    • product weight : 0.39 kg
  • Offer Sustainability
    • Sustainable offer status : Green Premium product
    • RoHS (date code: YYWW) : Compliant  - since  0706  -  Schneider Electric declaration of conformity 
    • REACh :
    • Product environmental profile : Available
    • Product end of life instructions : Available
  • Contractual warranty