9,3/10 out of 1126 reviews
SCHNEIDER

TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 630 A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC - LC1F630

LC1F630

obsolete product
Technical informations
Range of product: TeSys F
Range: TeSys
Product name: TeSys F
Product or component type: Contactor
Device short name: LC1F
Contactor application: Resistive loadMotor control
Utilisation category: AC-4AC-1AC-3
Poles description: 3P
Pole contact composition: 3 NO
[Ue] rated operational voltage:
[Ie] rated operational current: 1000 A (at 630 A (at
Motor power kW: 335 kW at 380...400 V AC 50/60 Hz (AC-3)375 kW at 415 V AC 50/60 Hz (AC-3)400 kW at 440 V AC 50/60 Hz (AC-3)400 kW at 500 V AC 50/60 Hz (AC-3)450 kW at 1000 V AC 50/60 Hz (AC-3)200 kW at 220...240 V AC 50/60 Hz (AC-3)450 kW at 660...690 V AC 50/60 Hz (AC-3)100 kW at 400 V AC 50/60 Hz (AC-4)
[Uc] control circuit voltage: 48...1000 V AC 40...400 Hz with LX1/LX9 coil48...440 V DC with LX4 coil
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 1000 A (at 40 °C)1250 A
Irms rated making capacity: 6300 A AC conforming to IEC 60947-4-1
Rated breaking capacity: 5040 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current: 5050 A 40 °C - 10 s4400 A 40 °C - 30 s3400 A 40 °C - 1 min2200 A 40 °C - 3 min1600 A 40 °C - 10 min
Associated fuse rating: 630 A aM at 1000 A gG at
Average impedance: 0.12 mOhm - Ith 1000 A 50 Hz
[Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-11500 V conforming to VDE 0110 group C
Control circuit voltage limits: Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coilDrop-out: 0.25...0.5 Uc AC 40...400 Hz with LX1/LX9 coilOperational: 0.85...1.1 Uc DC with LX4 coilDrop-out: 0.2...0.35 Uc DC with LX4 coil
Power dissipation per pole: 120 W AC-148 W AC-3
Heat dissipation: 20 W
Operating time: 40...80 ms closing for with LX1/LX9 coil100...200 ms opening for with LX1/LX9 coil60...70 ms closing for with LX4 coil40...50 ms opening for with LX4 coil
Mounting support: Plate
Standards: EN 60947-4-1IEC 60947-4-1IEC 60947-1JIS C8201-4-1EN 60947-1
Product certifications: ABSULRINADNVCSACBLROS (Lloyds register of shipping)BVRMRoSUKCA
Connections - terminals: Power circuit: bar 2 cable(s) - busbar cross section: 60 x 5 mmPower circuit: bolted connectionControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²solid without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²Control circuit: screw clamp terminals 2 cable(s) 1...4 mm²
Tightening torque: Power circuit: 58 N.mControl circuit: 1.2 N.m
Mechanical durability: 5 Mcycles
Inrush power in VA: 1500...1730 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil1420...1920 VA (at 20 °C)with LX4 coil
Hold-in power consumption in VA: 20...25 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil6.5...12.5 VA (at 20 °C)with LX4 coil
Maximum operating rate: 1200 cyc/h 55 °C
Compatibility code: LC1F
In short
Reference LC1F630
Product Name TeSys F contactor - 3P(3 NO)-AC-3 <= 440V 630 A with coil LX1/ LX9 - 48…1000V AC 40/400Hz, LX4 - 48...440V DC - LC1F630
Range TeSys
Related Categories