TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 24 V AC 50/60 Hz coil  - LC1D40AB7

Excl. Tax: €93.93 Incl. Tax: €93.93

Quick Overview - TeSys D - LC1D40AB7

  • Main
    • range of product : TeSys D
    • range : TeSys
    • product name : TeSys D
    • product or component type : Contactor
    • device short name : LC1D
    • contactor application : Resistive load
      Motor control
    • utilisation category : AC-1
      AC-3
      AC-4
    • poles description : 3P
    • pole contact composition : 3 NO
    • [Ue] rated operational voltage : <= 300 V DC for power circuit
      <= 690 V AC 25...400 Hz for power circuit
    • [Ie] rated operational current : 40 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
      60 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
    • motor power kW : 18.5 kW at 380...400 V AC 50/60 Hz AC-3
      22 kW at 500 V AC 50/60 Hz AC-3
      30 kW at 660...690 V AC 50/60 Hz AC-3
      11 kW at 220...230 V AC 50/60 Hz AC-3
      9 kW at 400 V AC 50/60 Hz AC-4
      22 kW at 415...440 V AC 50/60 Hz AC-3
    • motor power hp : 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors
      10 hp at 230/240 V AC 50/60 Hz for 3 phases motors
      30 hp at 575/600 V AC 50/60 Hz for 3 phases motors
      3 hp at 115 V AC 50/60 Hz for 1 phase motors
      10 hp at 200/208 V AC 50/60 Hz for 3 phases motors
      30 hp at 460/480 V AC 50/60 Hz for 3 phases motors
    • control circuit type : AC 50/60 Hz
    • [Uc] control circuit voltage : 24 V AC 50/60 Hz
    • auxiliary contact composition : 1 NO + 1 NC
    • [Uimp] rated impulse withstand voltage : Conforming to IEC 60947
    • overvoltage category : III
    • [Ith] conventional free air thermal current : 60 A at <= 60 °C for power circuit
      10 A at <= 60 °C for signalling circuit
    • Irms rated making capacity : 800 A at 440 V for power circuit conforming to IEC 60947
      140 A AC for signalling circuit conforming to IEC 60947-5-1
      250 A DC for signalling circuit conforming to IEC 60947-5-1
    • rated breaking capacity : 800 A at 440 V for power circuit conforming to IEC 60947
    • [Icw] rated short-time withstand current : 100 A 1 s signalling circuit
      120 A 500 ms signalling circuit
      140 A 100 ms signalling circuit
      320 A <= 40 °C 10 s power circuit
      720 A <= 40 °C 1 s power circuit
      72 A <= 40 °C 10 min power circuit
      165 A <= 40 °C 1 min power circuit
    • associated fuse rating : 80 A gG at <= 690 V coordination type 1 for power circuit
      80 A gG at <= 690 V coordination type 2 for power circuit
      10 A gG for signalling circuit conforming to IEC 60947-5-1
    • average impedance : 1.5 mOhm at 50 Hz - Ith 60 A for power circuit
    • [Ui] rated insulation voltage : 600 V for power circuit certifications CSA
      600 V for power circuit certifications UL
      690 V for power circuit conforming to IEC 60947-4-1
      690 V for signalling circuit conforming to IEC 60947-1
      600 V for signalling circuit certifications CSA
      600 V for signalling circuit certifications UL
    • electrical durability : 1.5 Mcycles 40 A AC-3 at Ue <= 440 V
      1.4 Mcycles 60 A AC-1 at Ue <= 440 V
    • power dissipation per pole : 5.4 W AC-1
      2.4 W AC-3
    • protective cover : With
    • mounting support : Plate
      Rail
    • standards : CSA C22.2 No 14
      EN 60947-4-1
      EN 60947-5-1
      IEC 60947-4-1
      IEC 60947-5-1
      UL 508
    • product certifications : UL
      CCC
      GOST
      CSA
    • connections - terminals : Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
      Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
      Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
      Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end
      Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
      Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
      Power circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: flexible - with cable end
      Power circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: solid - without cable end
      Power circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: flexible - without cable end
      Power circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: solid - without cable end
      Power circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: flexible - without cable end
      Power circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: flexible - with cable end
    • tightening torque : Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
      Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
      Power circuit : 8 N.m - on EverLink BTR screw connectors - cable 25...35 mm² hexagonal 4 mm
      Power circuit : 5 N.m - on EverLink BTR screw connectors - cable 1...25 mm² hexagonal 4 mm
    • operating time : 12...26 ms closing
      4...19 ms opening
    • safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
      B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    • mechanical durability : 6 Mcycles
    • operating rate : 3600 cyc/h at <= 60 °C

Details - Contactor - LC1D

  • Complementary
    • coil technology : Without built-in suppressor module
    • control circuit voltage limits : 0.3...0.6 Uc drop-out at 60 °C, AC 50/60 Hz
      0.8...1.1 Uc operational at 60 °C, AC 50 Hz
      0.85...1.1 Uc operational at 60 °C, AC 60 Hz
    • inrush power in VA : 140 VA at 20 °C (cos ϕ 0.75) 60 Hz
      160 VA at 20 °C (cos ϕ 0.75) 50 Hz
    • hold-in power consumption in VA : 13 VA at 20 °C (cos ϕ 0.3) 60 Hz
      15 VA at 20 °C (cos ϕ 0.3) 50 Hz
    • heat dissipation : 4...5 W at 50/60 Hz
    • auxiliary contacts type : Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
      Type mirror contact (1 NC) conforming to IEC 60947-4-1
    • signalling circuit frequency : 25...400 Hz
    • minimum switching current : 5 mA for signalling circuit
    • minimum switching voltage : 17 V for signalling circuit
    • non-overlap time : 1.5 ms on de-energisation (between NC and NO contact)
      1.5 ms on energisation (between NC and NO contact)
    • insulation resistance : > 10 MOhm for signalling circuit
    • motor power range AC-3 : 7...11 kW 200...240 V 3 phases
      15...25 kW 380...440 V 3 phases
      15...25 kW 480...500 V 3 phases
    • motor starter type : Direct on-line contactor
    • contactor coil voltage : 24 V AC standard

Additional Information - LC1D - TeSys - LC1D40AB7

Manufacturer Schneider
Code EAN 3389119408325
Plus d'infos
  • Environment
    • IP degree of protection : IP2x front face conforming to IEC 60529
    • protective treatment : TH conforming to IEC 60068-2-30
    • pollution degree : 3
    • ambient air temperature for operation : -5...60 °C
    • ambient air temperature for storage : -60...80 °C
    • permissible ambient air temperature around the device : -40...70 °C at Uc
    • operating altitude : 3000 m without derating in temperature
    • fire resistance : 850 °C conforming to IEC 60695-2-1
    • flame retardance : V1 conforming to UL 94
    • mechanical robustness : Vibrations contactor open 2 Gn, 5...300 Hz
      Vibrations contactor closed 4 Gn, 5...300 Hz
      Shocks contactor open 10 Gn for 11 ms
      Shocks contactor closed 15 Gn for 11 ms
    • height : 122 mm
    • width : 55 mm
    • depth : 120 mm
    • product weight : 0.85 kg
  • Offer Sustainability
    • Sustainable offer status : Green Premium product
    • RoHS (date code: YYWW) : Compliant  - since  0001  -  Schneider Electric declaration of conformity 
    • REACh :
    • Product environmental profile : Available
    • Product end of life instructions : Available
  • Contractual warranty
    • Warranty period : 18 months