circuit breaker ComPacT NSX400HB1, 75 kA at 690 VAC, MicroLogic 6.3 E trip unit 400 A, 4 poles 4d - C40V46E400

C40V46E400

€3,093.93 Excl. Tax
€3,712.72 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa payplug fintecture alma
Technical informations
Range: ComPacT new generation
Product name: ComPacT NSX new generation
Range of product: ComPacT NSX400...630 new generation
Device short name: NSX400HB1
Product or component type: Circuit breaker
Device application: Distribution
Poles description: 4P
Protected poles description: 4D3D + OSN3D + N/23D
Neutral position: Left
[In] rated current: 400 A at 40 °C
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Suitability for isolation: Yes conforming to EN/IEC 60947-2
Utilisation category: Category A
Breaking capacity: 85 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-280 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-275 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code: HB1 75 kA 690 V AC
Trip unit name: Micrologic 6.3 E
Trip unit technology: Electronic
Trip unit protection functions: LSIG
Control type: Toggle
Mounting mode: Fixed
[Ui] rated insulation voltage: 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV
[Ics] rated service breaking capacity: 85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-280 kA at 525 V AC 50/60 Hz conforming to IEC 60947-275 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability: 15000 cycles
Electrical durability: 12000 cycles at 440 V In/26000 cycles at 440 V In6000 cycles at 690 V In/23000 cycles at 690 V In
Power dissipation per pole: 19.2 W
Mounting support: Backplate
Mounting position: Horizontal and verticalFlat on the back
Upside connection: Front
Downside connection: Front
Connection pitch: 45 mm
Protection type: L
Trip unit rating: 400 A at 40 °C
Long time pick-up adjustment type Ir: Adjustable 9 settings
Long time pick-up adjustment range: 160...400 A
Long time delay adjustment type: Adjustable
[tr] long-time delay adjustment range: 15...400 s at 1.5 x Ir0.5...16 s at 6 x Ir0.35...11 s at 7.2 x Ir
Neutral protection setting: 0.5 x Ir (3D + N/2)1 x Ir (4D)1.6 x Ir (3D + OSN)No protection (3D)
Thermal memory: 20 minutes before and after tripping
Short-time pick-up adjustment type Isd: Adjustable
[Isd] short-time pick-up adjustment range: 1.5...12 x In
Short-time delay adjustment type: Adjustable 5 settings
[tsd] short-time delay adjustment range: 0...0.4 s I²t=off0.1...0.4 s I²t=on
Instantaneous pick-up adjustment type Ii: Adjustable
Instantaneous pick-up adjustment range: 1.5...12 x In
Ground-fault pick-up adjustment type: Adjustable 9 settings
[Ig] ground-fault pick-up adjustment range: 0.2...1 x InIg enable on/off
Ground-fault time delay adjustment type -tg: Adjustable 5 settings
[tg] ground-fault time delay adjustment range: 0...0.4 s I²t=off0.1...0.4 s I²t=on
Earth-leakage protection: Without
Zone selective interlocking ZSI: With
Number of slots: 6 slot(s)
Local signalling: Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload
Display type: LCD display
Type of measurement: Energy meter
Communication of data: Demand current and powerTime-stamped histories and event tablesProtection and alarm settingsEnergy meteringMaximeters/minimetersMaintenance indicatorsPower qualityInstantaneous and demand values
Width: 185 mm
Height: 255 mm
Depth: 110 mm
Net weight: 7.9 kg
Compatibility code: NSX400