9,3/10 out of 1126 reviews
⚠️ EXCEPTIONAL CLOSURE: No shipments from May 8th to 12th! Shipments will resume on May 13th ⚠️
SCHNEIDER

trip unit MicroLogic 6.2 E for ComPacT NSX 160/250 circuit breakers, electronic, rating 160A, 4 poles 4d - C1646E160

C1646E160

€866.53 Excl. Tax
€1,039.84 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa payplug fintecture alma
Technical informations
Range: ComPacT new generation
Range of product: ComPacT NSX100...250 new generation
Product or component type: Trip unit
Trip unit name: Micrologic 6.2 E
Trip unit technology: Electronic
Range compatibility: ComPacT new generation NSX160ComPacT new generation NSX250
Device application: Distribution
Poles description: 4P
Protected poles description: 3D + N/24D3D + OSN3D
Neutral position: Left
Trip unit protection functions: LSIG
Protection type: L
[In] rated current: 160 A at 40 °C
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Mounting mode: Fixed
Long time pick-up adjustment type Ir: Adjustable 9 settings
Long time pick-up adjustment range: 63...160 A
Long time delay adjustment type: Adjustable
[tr] long-time delay adjustment range: 15...400 s at 1.5 x Ir0.35...11 s at 7.2 x Ir0.5...16 s at 6 x Ir
Neutral protection setting: 0.5 x Ir (3D + N/2)1 x Ir (4D)1.6 x Ir (3D + OSN)No protection (3D)
Thermal memory: 20 minutes before and after tripping
Short-time pick-up adjustment type Isd: Adjustable 9 settings
[Isd] short-time pick-up adjustment range: 1.5...10 x Ir
Short-time delay adjustment type: Adjustable
[tsd] short-time delay adjustment range: 0...0.4 s I²t=off0.1...0.4 s I²t=on
Instantaneous pick-up adjustment type Ii: Adjustable
Instantaneous pick-up adjustment range: 1.5...15 x In
Ground-fault pick-up adjustment type: Adjustable
[Ig] ground-fault pick-up adjustment range: 0.4...1 x In for In = 40 A0.2...1 x In for In > 40 AIg enable on/off
Ground-fault time delay adjustment type -tg: Adjustable
[tg] ground-fault time delay adjustment range: 0...0.4 s I²t=off0.1...0.4 s I²t=on
Earth-leakage protection: Without
Zone selective interlocking ZSI: With
Local signalling: Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload
Display type: LCD display
Type of measurement: Energy meter
Communication of data: Energy meteringProtection and alarm settingsTime-stamped histories and event tablesInstantaneous and demand valuesMaintenance indicatorsDemand current and powerPower qualityMaximeters/minimeters
Electrical data recording: Maintenance indicators
In short
Reference C1646E160
Product Name trip unit MicroLogic 6.2 E for ComPacT NSX 160/250 circuit breakers, electronic, rating 160A, 4 poles 4d - C1646E160
Range ComPacT nouvelle génération
Related Categories