9,3/10 out of 1126 reviews
SCHNEIDER

Trip unit, ComPacT NSX160, AC, 4P4D, 160 A, Mic6.2A - C1646A160

C1646A160

€1,155.53 Excl. Tax
€1,386.64 Inc. Tax
preorder Supply in process – Average delivery time 4/6 weeks
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa payplug fintecture alma
Technical informations
Range of product: ComPacT NSX100...250 new generation
Product or component type: Trip unit
Poles description: 4P
Protected poles description: 4D
Neutral position: Left
Network type: AC
Network frequency: 50/60 Hz
Trip unit name: Micrologic 6.2 A
Trip unit technology: Electronic
Trip unit protection functions: LSIG
Trip unit rating: 160 A at 40 °C
Protection type: Overload (long time)Short time short-circuit protectionInstantaneous short-circuit protection
Mounting mode: Fixed
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Neutral protection setting: No protection0.5 x Ir1 x Ir
Long time pick-up adjustment type Ir: Adjustable 9 settings
Long time pick-up adjustment range: 63...160 A
Long time delay adjustment type: Adjustable
[tr] long-time delay adjustment range: 15...400 s 1.5 x Ir0.5...16 s 6 x Ir0.35...11 s 7.2 x Ir
Thermal memory: 20 minutes before and after tripping
Short-time pick-up adjustment type Isd: Adjustable 9 settings
[Isd] short-time pick-up adjustment range: 1.5...10 x Ir
Short-time delay adjustment type: Adjustable
[tsd] short-time delay adjustment range: 0...0.4 s I²t=off0.1...0.4 s I²t=on
Instantaneous pick-up adjustment type Ii: Adjustable
Instantaneous pick-up adjustment range: 1.5...15 x In, accuracy: +/- 15 %
Ground-fault time delay adjustment type -tg: Adjustable
Ground-fault pick-up adjustment type: Adjustable
[tg] ground-fault time delay adjustment range: 0...0.4 s I²t=off0.1...0.4 s I²t=on
[Ig] ground-fault pick-up adjustment range: 0.2...1 x In (In > 40 A), accuracy: +/- 10 %0.4...1 x In (In = 40 A), accuracy: +/- 10 %Ig enable on/off
Zone selective interlocking ZSI: With
Communication of data: Demand current and powerInstantaneous and demand valuesMaintenance indicatorsEarth leakage current
Display type: LCD display
Type of measurement: Ammeter
Electrical data recording: Maintenance indicators
Compatibility code: NSX160
Communication port protocol: Modbus