9,3/10 out of 1126 reviews
SCHNEIDER

PowerPact-circuit breaker-60A 3P AC 35kA at 480/440V(UL/IEC)-TMD-EverLink lug - BGL36060LU

BGL36060LU

€397.18 Excl. Tax
€476.62 Inc. Tax
available In stock – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 100€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa payplug fintecture alma
Technical informations
Range: PowerPact
Product name: PowerPact B
Device short name: BG 060
Product or component type: Circuit breaker
Device application: Distribution
[In] rated current: 60 A
Poles description: 3P
Protected poles description: 3t
Control type: Toggle
Breaking capacity code: G
Breaking capacity: 65 kA at 208Y/120 V AC 50/60 Hz conforming to UL 489 65 kA at 240 V AC 50/60 Hz conforming to UL 489 35 kA at 480/277 V AC 50/60 Hz conforming to UL 489 35 kA at 480 V AC 50/60 Hz conforming to UL 489 20 kA at 250 V DC conforming to UL 489 18 kA at 600Y/347 V AC 50/60 Hz conforming to UL 489
[Ue] rated operational voltage: 525 V AC 50/60 Hz conforming to UL 489
Network frequency: 50/60 Hz
[Ics] rated service breaking capacity: 65 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-218 kA at 500...525 V AC 50/60 Hz conforming to IEC 60947-235 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-235 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2
Trip unit technology: Thermal-magneticTM-D,
Continuous current rating: 80 %
[Ui] rated insulation voltage: 800 V conforming to IEC 60947-2
Trip unit name: TM-D
Suitability for isolation: Yes conforming to IEC 60947-2
Utilisation category: Category A
Mechanical durability: 15000 cycles conforming to IEC 947-1 Annex K ed 5.2
Electrical durability: 10000 cycles conforming to IEC 947-1 Annex K ed 5.2 at 440 V In
Connection pitch: 27 mm
AWG gauge: AWG 6...AWG 2/0 fine stranded aluminium/copperAWG 14...AWG 3/0 rigid or stranded aluminium/copper
Local signalling: Presence of auxiliary contacts: flag (green)
Mounting mode: Clip-on (35 mm symmetrical DIN rail)By screws (plate)
Electrical connection: Everlink lug lineEverlink lug load
Tightening torque: 5 N.m for 2.5...16 mm² (AWG 14...AWG 4)9 N.m for 25...95 mm² (AWG 3...AWG 3/0)
Number of slots: 1 slot(s) for auxiliary switch OF (plug-in)1 slot(s) for voltage release MN or MX (plug-in)1 slot(s) for alarm switch SD (plug-in)
Wire stripping length: 20 mm
Colour: Grey (RAL 7016)
9 mm pitches: 9
Height: 137 mm
Width: 81 mm
Depth: 80 mm
Net weight: 1.074 kg
Quantity per set: Set of 1
Circuit breaker application: HACR rated
In short
Reference BGL36060LU
Product Name PowerPact-circuit breaker-60A 3P AC 35kA at 480/440V(UL/IEC)-TMD-EverLink lug - BGL36060LU
Range PowerPact
Related Categories