Technical informations
Range of product: RED
Range: Acti 9
Product or component type: Residual current circuit breaker (RCCB)
Device short name: REDs
Protection type: Recloser
Poles description: 2P
Neutral position: Left
Signal contacts composition: 1NO or 1NC or intermittent 1 Hz
[In] rated current: 63 A
Earthing system: TN-STT
Network type: AC
Earth-leakage sensitivity: 300 mA
Device location in system: Outgoer
Network frequency: 50 Hz
[Ue] rated operational voltage: 230 V AC 50 Hz phase to neutral
Reset: Fault reset earth leakage
Test function: Manual at > 100 V
Earth-leakage protection time delay: Instantaneous
Earth-leakage protection class: Type A
Minimum leakage resistance: 5 kOhm at operating2.5 kOhm at non-operating
[Im] rated making and breaking capacity: Idm 630 A 230 V
Rated conditional short-circuit current: Inc: 15 kA - associated with NG125, 40 AInc: 10 kA - associated with iC60L, 63 AInc: 15 kA - associated with iC60L, 40 AInc: 10 kA - associated with C120H, 63 AInc: 10 kA - associated with iC60N, 63 AInc: 25 kA - associated with gG fuse, 25 AInc: 15 kA - associated with gG fuse, 40 AInc: 10 kA - associated with NG125, 63 AInc: 15 kA - associated with iC60H, 40 AInc: 10 kA - associated with C120L, 63 AInc: 10 kA - associated with iC60H, 63 AInc: 10 kA - associated with gG fuse, 63 AInc: 10 kA - associated with C120N, 63 A
[Ui] rated insulation voltage: 500 V
[Uimp] rated impulse withstand voltage: 4 kV
Surge current: 250 A
Control type: Toggle
Local signalling: 2 LEDsResidual current device
Operating mode: Reclosing time: Max nb of consecutive restart: 3Min interval between 2 closings: 180 sStopping restart cycle if insulation fault presentInsulation fault presence monitoring
Signalling circuit voltage: AC: 5...230 VDC: 5...230 V
Mounting mode: Fixed
Mounting support: 35 mm symmetrical DIN rail
9 mm pitches: 8
Height: 115 mm
Width: 71 mm
Depth: 79.5 mm
Product weight: 0.36 kg
Mechanical durability: 1000 cycles open-close
Connections - terminals: Guard tunnel terminal 35 mm² rigidGuard tunnel terminal 35 mm² flexibleGuard tunnel terminal 35 mm² flexible with ferrule
Auxiliary connection terminal: Tunnel type terminal in 2.5 mm² flexibleTunnel type terminal in 2.5 mm² rigidTunnel type terminal in 2.5 mm² flexible with ferrule
Wire stripping length: Power circuit: 12 mmSignaling: 9 mm
Tightening torque: Power circuit: 2 N.mSignaling: 0.4 N.m
Compatibility code: REDs