Informations techniques
Range of product : TeSys K
Range : TeSys
Product or component type : Contactor
Product name : TeSys K
Device short name : LC1K
Device application : Control
Contactor application : Motor controlResistive load
Utilisation category : AC-3AC-1
Poles description : 3P
Pole contact composition : 3 NO
[Ue] rated operational voltage : Power circuit: 690 V AC 50/60 HzSignalling circuit:
[Ie] rated operational current : 6 A at
Control circuit type : DC low consumption
[Uc] control circuit voltage : 24 V DC
Motor power kW : 1.5 kW at 220...230 V AC 50/60 Hz2.2 kW at 380...415 V AC 50/60 Hz3 kW at 500...600 V AC 50/60 Hz3 kW at 440/500 V AC 50/60 Hz3 kW at 660/690 V AC 50/60 Hz0.37 kW at 115 V AC 50/60 Hz0.75 kW at 220 V AC 50/60 Hz
Auxiliary contact composition : 1 NC
[Uimp] rated impulse withstand voltage : 8 kV
Overvoltage category : III
[Ith] conventional free air thermal current : 20 A (at 50 °C) for power circuit10 A (at 50 °C) for signalling circuit
Irms rated making capacity : 110 A AC for power circuit conforming to NF C 63-110110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity : 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
[Icw] rated short-time withstand current : 90 A 50 °C - 1 s for power circuit85 A 50 °C - 5 s for power circuit80 A 50 °C - 10 s for power circuit60 A 50 °C - 30 s for power circuit45 A 50 °C - 1 min for power circuit40 A 50 °C - 3 min for power circuit20 A 50 °C - >= 15 min for power circuit80 A - 1 s for signalling circuit90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit
Associated fuse rating : 25 A gG at 10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660
Average impedance : 3 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage : Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Power circuit: 750 V conforming to VDE 0110 group CPower circuit: 690 V conforming to BS 5424Power circuit: 690 V conforming to NF C 20-040
Insulation resistance : > 10 MOhm for signalling circuit
Inrush power in W : 1.8 W (at 20 °C)
Hold-in power consumption in W : 1.8 W at 20 °C
Heat dissipation : 1.8 W
Control circuit voltage limits : Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at
Connections - terminals : Power circuit: lugs-ring terminals (external diameter: 7 mm)
Maximum operating rate : 3600 cyc/h
Coil technology : With integral suppression device
Auxiliary contacts type : type instantaneous 1 NC
Signalling circuit frequency :
Minimum switching current : 5 mA for signalling circuit
Minimum switching voltage : 17 V for signalling circuit
Mounting support : RailPlate
Tightening torque : Power circuit: 1.3 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm3.2 mmPower circuit: 1.3 N.m - on lugs-ring terminals - with screwdriver Philips No 23.2 mm
Operating time : 10...20 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing
Safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance : 0.5 mm
Mechanical durability : 30 Mcycles
Electrical durability : 1.3 Mcycles 6 A AC-3 at Ue
Mechanical robustness : Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Height : 58 mm
Width : 45 mm
Depth : 57 mm
Product weight : 0.235 kg
En bref
Référence LC1K06016BLS207
Nom du produit TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NC aux. - 24 V DC low - LC1K06016BLS207