Informations techniques
| Device application : | Distribution |
|---|---|
| Range : | Acti 9 |
| Product name : | Acti 9 iC60 |
| Product or component type : | Miniature circuit-breaker |
| Device short name : | IC60N |
| Poles description : | 1P |
| Number of protected poles : | 1 |
| [In] rated current : | 32 A |
| Network type : | ACDC |
| Trip unit technology : | Thermal-magnetic |
| Curve code : | C |
| Breaking capacity : | 10 kA Icu conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz20 kA Icu conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz6000 A Icn conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz10 kA Icu conforming to EN/IEC 60947-2 - 60...72 V DC15 kA Icu conforming to EN/IEC 60947-2 - 12...60 V DC36 kA Icu conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz |
| Utilisation category : | Category A conforming to EN 60898-1Category A conforming to IEC 60898-1 |
| Suitability for isolation : | Yes conforming to EN 60947-2Yes conforming to IEC 60947-2Yes conforming to EN 60898-1Yes conforming to IEC 60898-1 |
| Standards : | EN 60898-1EN 60947-2IEC 60898-1IEC 60947-2 |
| Network frequency : | 50/60 Hz |
|---|---|
| Magnetic tripping limit : | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity : | 10 kA 100 % x Icu conforming to EN 60947-2 - 72 V DC10 kA 100 % x Icu conforming to IEC 60947-2 - 72 V DC6000 A 100 % x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz15 kA 100 % x Icu conforming to EN 60947-2 - 12...60 V DC15 kA 100 % x Icu conforming to IEC 60947-2 - 12...60 V DC6000 A 100 % x Icu conforming to EN 60898-1 - 230 V AC 50/60 Hz27 kA 75 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz7.5 kA 75 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz27 kA 75 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz7.5 kA 75 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz15 kA 75 % x Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz15 kA 75 % x Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz |
| Limitation class : | 3 conforming to EN 60898-13 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage : | 500 V AC 50/60 Hz conforming to IEC 60947-2500 V AC 50/60 Hz conforming to EN 60947-2 |
| [Uimp] rated impulse withstand voltage : | 6 kV conforming to EN 60947-26 kV conforming to IEC 60947-2 |
| Contact position indicator : | Yes |
| Control type : | Toggle |
| Local signalling : | Trip indicator |
| Mounting support : | DIN rail |
| 9 mm pitches : | 2 |
| Height : | 91 mm |
| Width : | 18 mm |
| Depth : | 78.5 mm |
| Product weight : | 0.125 kg |
| Colour : | White |
| Mechanical durability : | 20000 cycles |
| Electrical durability : | 10000 cycles |
| Connections - terminals : | Double terminal, top or bottom rigid wire(s) 1...35 mm² maxDouble terminal, top or bottom flexible wire(s) 1...25 mm² max |
| Wire stripping length : | 14 mm top or bottom |
| Tightening torque : | 3.5 N.m top or bottom |
| Earth-leakage protection : | Without |