Range of product: | Preventa Safety automation |
---|
Product or component type: | Preventa safety module |
---|
Safety module name: | XPSAC |
---|
Safety module application: | For emergency stop and switch monitoring |
---|
Function of module: | Emergency stopSwitch monitoring |
---|
Safety level: | Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061 |
---|
Safety reliability data: | MTTFd = 210.4 years conforming to EN/ISO 13849-1DC > 99 % conforming to EN/ISO 13849-1PFHd = 3.56E-9 1/h conforming to EN/IEC 62061 |
---|
Type of start: | Unmonitored |
---|
Connections - terminals: | Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable endCaptive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable endCaptive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezelCaptive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezelCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable endCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable endCaptive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezelCaptive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
---|
Output type: | Relay instantaneous opening, 3 NO circuit(s), volt-free |
---|
Number of additional circuits: | 1 solid state output |
---|
[Us] rated supply voltage: | 24 V AC - 20...10 %24 V DC - 20...20 % |
---|