Height: | 42 mm |
---|
Width: | 30 mm |
---|
Depth: | 54 mm |
---|
Terminals description ISO n°1: | (21-22)NC(13-14)NO |
---|
Product weight: | 0.057 kg |
---|
Resistance to high pressure washer: | 7000000 Pa at 55 °C,distance: 0.1 m |
---|
Contacts usage: | Standard contacts |
---|
Positive opening: | With positive opening conforming to EN/IEC 60947-5-1 appendix K |
---|
Operating travel: | 1.5 mm (NC changing electrical state)2.6 mm (NO changing electrical state)4.3 mm (total travel) |
---|
Operating force: | 3.5 N (NC changing electrical state)3.8 N |
---|
Mechanical durability: | 10000000 cycles |
---|
Tightening torque: | 0.8...1.2 N.m conforming to EN 60947-1 |
---|
Shape of screw head: | Cross head compatible with Philips no 1 screwdriverCross head compatible with pozidriv No 1 screwdriverSlotted head compatible with flat Ø 4 mm screwdriverSlotted head compatible with flat Ø 5.5 mm screwdriver |
---|
Contacts material: | Silver alloy (Ag/Ni) |
---|
Short circuit protection: | 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 |
---|
[Ith] conventional free air thermal current: | 10 A conforming to EN/IEC 60947-5-1 |
---|
[Ui] rated insulation voltage: | 600 V (degree of pollution: 3) conforming to EN/IEC 60947-1 |
---|
[Uimp] rated impulse withstand voltage: | 6 kV conforming to EN/IEC 60947-1 |
---|
[Ie] rated operational current: | 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-16 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-10.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-10.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-10.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-11.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
---|
Electrical durability: | 1000000 cycles, AC-15, 2 A at 230 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C1000000 cycles, AC-15, 3 A at 120 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C1000000 cycles, AC-15, 4 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C1000000 cycles, DC-13, 0.2 A at 110 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C1000000 cycles, DC-13, 0.5 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
---|
Electrical reliability: | ? ? |
---|
Signalling type: | Steady |
---|