Modicon TM3, module 32 entrées 24VCC, connecteur HE 10 - TM3DI32K
TM3DI32K
- Technical support and dedicated single point of contact
- Free delivery from 100€ of purchase (Metropolitan France)
- 100% secure payments
Range of product: | Modicon TM3 |
---|---|
Product or component type: | Discrete input module |
Range compatibility: | Modicon M221Modicon M251Modicon M241 |
Discrete input number: | 32 input conforming to IEC 61131-2 Type 1 |
Discrete input logic: | Sink or source (positive/negative) |
Discrete input voltage: | 24 V |
Discrete input current: | 5 mA for input |
Discrete I/O number: | 32 |
---|---|
Current consumption: | 5 mA at 5 V DC via bus connector at state off0 mA at 24 V DC via bus connector at state on0 mA at 24 V DC via bus connector at state off65 mA at 5 V DC via bus connector at state on |
Discrete input voltage type: | DC |
Voltage state1 guaranteed: | 15...28.8 V for input |
Current state 1 guaranteed: | >= 2.5 mA for input |
Voltage state 0 guaranteed: | 0...5 V for input |
Current state 0 guaranteed: | |
Input impedance: | 4.4 kOhm |
Response time: | 4 ms for turn-on4 ms for turn-off |
Local signalling: | 1 LED per channel green for input status |
Electrical connection: | HE-10 connector for inputs |
Cable length: | |
Insulation: | Non-insulated between inputs500 V AC between input and internal logic |
Marking: | CE |
Mounting support: | Top hat type TH35-15 rail conforming to IEC 60715Top hat type TH35-7.5 rail conforming to IEC 60715Plate or panel with fixing kit |
Height: | 90 mm |
Depth: | 81.3 mm |
Width: | 33.5 mm |
Product weight: | 0.1 kg |
Standards: | EN/IEC 61131-2EN/IEC 61010-2-201 |
---|---|
Product certifications: | C-TickcULus |
Resistance to electrostatic discharge: | 4 kV (on contact) conforming to EN/IEC 61000-4-28 kV (in air) conforming to EN/IEC 61000-4-2 |
Resistance to electromagnetic fields: | 10 V/m at 80 MHz...1 GHz conforming to EN/IEC 61000-4-33 V/m at 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-31 V/m at 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 |
Resistance to magnetic fields: | 30 A/m at 50...60 Hz conforming to EN/IEC 61000-4-8 |
Resistance to fast transients: | 1 kV for I/O conforming to EN/IEC 61000-4-4 |
Surge withstand: | 1 kV for I/O (DC) in common mode conforming to EN/IEC 61000-4-5 |
Resistance to conducted disturbances, induced by radio frequency fields: | 10 Vrms at 0.15...80 MHz conforming to EN/IEC 61000-4-63 Vrms at spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
Electromagnetic emission: | Radiated emissions, test level: 40 dB?V/m QP with class A, condition of test: 10 m (radio frequency: 30...230 MHz) conforming to EN/IEC 55011Radiated emissions, test level: 47 dB?V/m QP with class A, condition of test: 10 m (radio frequency: 230 MHz...1 GHz) conforming to EN/IEC 55011 |
Ambient air temperature for operation: | -10...55 °C for horizontal installation-10...35 °C for vertical installation |
Ambient air temperature for storage: | -25...70 °C |
Relative humidity: | 10...95 % without condensation in operation10...95 % without condensation in storage |
IP degree of protection: | IP20 with protective cover in place |
Pollution degree: | 2 |
Operating altitude: | 0...2000 m |
Storage altitude: | 0...3000 m |
Vibration resistance: | 3.5 mm (vibration frequency: 5...8.4 Hz) on DIN rail3 gn (vibration frequency: 8.4...150 Hz) on DIN rail3.5 mm (vibration frequency: 5...8.4 Hz) on panel3 gn (vibration frequency: 8.4...150 Hz) on panel |
Shock resistance: | 15 gn (test wave duration:11 ms) |
Sustainable offer status: | Green Premium productRoHS (date code: YYWW) |
Code EAN: | 3606480611414 |
---|---|
Contexte: | Modicon TM3 I/0 system - your choice for flexible and customisable expansion of I/O terminals! The specially developed Modicon TM3 I/O system enables flexible and customisable expansion of the I/O terminals in all of the controllers. Up to 14 terminals can be added to the controllers without tools. When the terminals are plugged in, their contacts are electrically linked to both the controller and the adjacent terminal. This high-speed expansion bus is 10 times faster than traditional solutions. The Modicon TM3 offer provides a large range of I/O systems to enhance the capabilities of Modicon M221, M241 and M251 logic controllers:In addition, the Modicon TM3 expansion system is flexible due to the possibility of remotely locating some of the Modicon TM3 modules in the enclosure or another cabinet (up to 5 meters away, using a bus expansion system. It is common to the whole range of Modicon M221, M241 and M251 logic controllers, meaning that the model of controller can be revised without changing expansion module. The Modicon TM3 is a MachineStruxure I/O system. The NEXT generation of MachineStruxure™ from Schneider Electric is an intuitive solution for machine automation with all the features and functions you need to build machines that will improve your bottom line. From design and development, to commissioning and maintenance, MachineStruxure is a complete machine building solution with benefits all through the machine life cycle. |