calcActive())">
SCHNEIDER
TeSys LC1D - contacteur - 4P - AC-1 440V - 40A - bobine 110Vca - LC1DT40F7
LC1DT40F7
€66.83 Excl. Tax
€80.20 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Availability: contact us
- Technical support and dedicated single point of contact
- Free delivery from 250€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
| Range of product: | TeSys D |
|---|---|
| Range: | TeSys |
| Product name: | TeSys D |
| Product or component type: | Contactor |
| Device short name: | LC1D |
| Contactor application: | Resistive load |
| Utilisation category: | AC-1 |
| Poles description: | 4P |
| Pole contact composition: | 4 NO |
| [Ue] rated operational voltage: | |
| [Ie] rated operational current: | 40 A ( |
| Control circuit type: | AC 50/60 Hz |
| [Uc] control circuit voltage: | 110 V AC 50/60 Hz |
| Auxiliary contact composition: | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage: | Conforming to IEC 60947 |
| Overvoltage category: | III |
| [Ith] conventional free air thermal current: | 40 A at 10 A at |
| Irms rated making capacity: | 450 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity: | 450 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current: | 120 A 240 A 380 A 50 A 100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit |
| Associated fuse rating: | 40 A gG at 63 A gG at 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
| Average impedance: | 2 mOhm at 50 Hz - Ith 40 A for power circuit |
| [Ui] rated insulation voltage: | 600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for power circuit conforming to IEC 60947-4-1690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications UL |
| Electrical durability: | 1.4 Mcycles 40 A AC-1 at Ue |
| Power dissipation per pole: | 3.2 W AC-1 |
| Protective cover: | With |
| Mounting support: | PlateRail |
| Standards: | CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508 |
| Product certifications: | LROSBVGLCCCDNVULCSAGOSTRINA |
| Connections - terminals: | Control circuit |
| Tightening torque: | Control circuit |
| Operating time: | 4...19 ms opening12...22 ms closing |
| Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability: | 15 Mcycles |
| Operating rate: | 3600 cyc/h at |
| Coil technology: | Without built-in suppressor module |
|---|---|
| Control circuit voltage limits: | 0.3...0.6 Uc drop-out at 60 °C, AC 50/60 Hz0.8...1.1 Uc operational at 60 °C, AC 50 Hz0.85...1.1 Uc operational at 60 °C, AC 60 Hz |
| Inrush power in VA: | 70 VA at 20 °C (cos ? 0.75) 60 Hz70 VA at 20 °C (cos ? 0.75) 50 Hz |
| Hold-in power consumption in VA: | 7.5 VA at 20 °C (cos ? 0.3) 60 Hz7 VA at 20 °C (cos ? 0.3) 50 Hz |
| Heat dissipation: | 2...3 W at 50/60 Hz |
| Auxiliary contacts type: | Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1 |
| Signalling circuit frequency: | 25...400 Hz |
| Minimum switching current: | 5 mA for signalling circuit |
| Minimum switching voltage: | 17 V for signalling circuit |
| Non-overlap time: | 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact) |
| Insulation resistance: | > 10 MOhm for signalling circuit |
In short
Reference LC1DT40F7
Product Name TeSys LC1D - contacteur - 4P - AC-1 440V - 40A - bobine 110Vca - LC1DT40F7
Range TeSys
Related Categories