Technical informations
| Range of product: | TeSys D |
|---|---|
| Range: | TeSysTeSys Deca |
| Product name: | TeSys DTeSys Deca |
| Product or component type: | Star delta starter |
| Device short name: | LC3D |
| Contactor application: | Motor control |
| Utilisation category: | AC-3 |
| Device presentation: | Pre-wired |
| Poles description: | 3 x 3P |
| Pole contact composition: | 3 x 3 NO |
| [Ue] rated operational voltage: | Power circuit: |
| [Ie] rated operational current: | 9Â A (at |
| Motor power kW: | 4Â kW at 220/230 V AC 50/60 Hz7.5Â kW at 380/400 V AC 50/60 Hz7.5Â kW at 415 V AC 50/60 Hz7.5Â kW at 440 V AC 50/60 Hz |
| Control circuit type: | AC at 50/60 Hz |
| [Uc] control circuit voltage: | 230 V AC 50/60 Hz |
| Auxiliary contact composition: | 1 NC for KM1 star contactor |
| [Uimp] rated impulse withstand voltage: | 6Â kV conforming to IEC 60947 |
| Overvoltage category: | III |
| [Ui] rated insulation voltage: | Power circuit: 690Â V conforming to IEC 60947-4-1Power circuit: 600Â V CSA certifiedPower circuit: 600Â V UL certifiedSignalling circuit: 690Â V conforming to IEC 60947-1Signalling circuit: 600Â V CSA certifiedSignalling circuit: 600Â V UL certified |
| Electrical durability: | 2Â Mcycles 9Â A AC-3 at Ue |
| Provided equipment: | Protective cover |
| Interlocking type: | Mechanical |
| Mounting support: | Rail |
| Standards: | IEC 60947-5-1CSA C22.2 No 14IEC 60947-4-1EN 60947-4-1UL 508EN 60947-5-1IEC 60335-1 |
| Product certifications: | RINACCCBVULGOSTLROS (Lloyds register of shipping)GLDNVCSA |
| Connections - terminals: | Power circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable endPower circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable endPower circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid without cable endPower circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable endControl circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable endControl circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid without cable endControl circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable end |
|---|---|
| Tightening torque: | Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmPower circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
| Mechanical durability: | 15Â Mcycles |
| Maximum operating rate: | 30 cyc/h 60 °C |
| Starting time: | 30 s |
| Coil technology: | Without built-in suppressor module |
| Control circuit voltage limits: | Drop-out: 0.3...0.6 Uc at 50/60 Hz (at Operational: 0.8...1.1 Uc at 50 Hz (at Operational: 0.85...1.1 Uc at 60 Hz (at |
| Inrush power in VA: | 70 VA 60 Hz cos phi 0.75 (at 20 °C)70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA: | 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation: | 2...3Â W at 50/60 Hz |
| Auxiliary contacts type: | Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NCMirror contact conforming to IEC 60947-4-1 3 x 1 NC |
| Signalling circuit frequency: | 25...400 Hz |
| Minimum switching current: | 5Â mA for signalling circuit |
| Switching voltage: | 17Â V for signalling circuit |
| Non-overlap time: | 1.5Â ms on de-energisation between NC and NO contact1.5Â ms on energisation between NC and NO contact |
| Width: | 143Â mm |
| Height: | 124Â mm |
| Depth: | 143Â mm |
| Product weight: | 1.53Â kg |
| Power range: | 4...6Â kW at 200...240Â V 3 phases7...11Â kW at 380...440Â V 3 phases4...6Â kW at 380...440Â V 3 phases2.2...3Â kW at 200...240Â V 3 phases |
| Motor starter type: | Star delta starter |
| Contactor coil voltage: | 230Â V AC standard |