Technical informations
| Range of product: | TeSys D |
|---|---|
| Range: | TeSys |
| Product name: | TeSys D |
| Product or component type: | Contactor |
| Device short name: | LC1D |
| Contactor application: | Resistive load |
| Utilisation category: | AC-1 |
| Poles description: | 4P |
| Pole contact composition: | 2 NO + 2 NC |
| [Ue] rated operational voltage: | Power circuit: Power circuit: |
| [Ie] rated operational current: | 80 A (at |
| Control circuit type: | AC at 50/60 Hz |
| [Uc] control circuit voltage: | 230 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947 |
| Overvoltage category: | III |
| [Ith] conventional free air thermal current: | 80 A (at 60 °C) for power circuit |
| Irms rated making capacity: | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity: | 1000 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current: | 520 A 40 °C - 10 s for power circuit900 A 40 °C - 1 s for power circuit110 A 40 °C - 10 min for power circuit260 A 40 °C - 1 min for power circuit |
| Associated fuse rating: | 125 A gG at 125 A gG at |
| Average impedance: | 1.5 mOhm - Ith 80 A 50 Hz for power circuit |
| [Ui] rated insulation voltage: | Power circuit: 600 V CSA certifiedPower circuit: 600 V UL certifiedPower circuit: 690 V conforming to IEC 60947-4-1 |
| Electrical durability: | 1.4 Mcycles 80 A AC-1 at Ue |
| Power dissipation per pole: | 9.6 W AC-1 |
| Protective cover: | Without |
| Mounting support: | RailPlate |
| Standards: | CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508 |
| Product certifications: | DNVGLLROS (Lloyds register of shipping)BVGOSTCCCRINACSAULUKCA |
| Connections - terminals: | Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²flexible with cable endControl circuit: screw clamp terminals 1 cable(s) 1...4 mm²solid without cable endControl circuit: screw clamp terminals 2 cable(s) 1...4 mm²solid without cable endPower circuit: screw clamp terminals 1 cable(s) 1...35 mm²flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1...25 mm²flexible without cable endPower circuit: screw clamp terminals 1 cable(s) 1...35 mm²flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1...25 mm²flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 1...35 mm²solid without cable endPower circuit: screw clamp terminals 2 cable(s) 1...25 mm²solid without cable end |
| Tightening torque: | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 8 N.m - on screw clamp terminals - cable 25...35 mm² hexagonal screw head 4 mmPower circuit: 5 N.m - on screw clamp terminals - cable 1...25 mm² hexagonal screw head 4 mm |
| Operating time: | 4...19 ms opening12...26 ms closing |
| Safety reliability level: | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability: | 6 Mcycles |
| Maximum operating rate: | 3600 cyc/h 60 °C |
| Coil technology: | Without built-in suppressor module |
|---|---|
| Control circuit voltage limits: | 0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.1 Uc (-40...60 °C):operational AC 50 Hz0.85...1.1 Uc (-40...60 °C):operational AC 60 Hz1...1.1 Uc (60...70 °C):operational AC 50/60 Hz |
| Inrush power in VA: | 140 VA 60 Hz cos phi 0.75 (at 20 °C)160 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA: | 13 VA 60 Hz cos phi 0.3 (at 20 °C)15 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation: | 4...5 W at 50/60 Hz |
| Contact compatibility: | M1 |
| Compatibility code: | LC1D |