calcActive())">
SCHNEIDER
soft starter for asynchronous motor - ATS48 - 42 A - 230..415 V - 9..45 KW - ATS48D47Q
ATS48D47Q
Ce produit n'est plus disponible. Contactez-nous pour une solution de remplacement adaptée à vos besoins.
Technical informations
| Range of product: | Altistart 48 |
|---|---|
| Product or component type: | Soft starter |
| Product destination: | Asynchronous motors |
| Product specific application: | Heavy duty industry and pumps |
| Device short name: | ATS48 |
| [Us] rated supply voltage: | 230...415 V - 15...10 % |
| Motor power kW: | 9 kW at 230 V connection in the motor supply line for severe applications11 kW at 230 V connection in the motor supply line for standard applications18.5 kW at 230 V connection to the motor delta terminals for severe applications18.5 kW at 400 V connection in the motor supply line for severe applications22 kW at 230 V connection to the motor delta terminals for standard applications22 kW at 400 V connection in the motor supply line for standard applications30 kW at 400 V connection to the motor delta terminals for severe applications45 kW at 400 V connection to the motor delta terminals for standard applications |
| Power dissipation in W: | 116 W for severe applications142 W for standard applications |
| Utilisation category: | AC-53A |
| Type of start: | Start with torque control (current limited to 5 In) |
| IcL starter rating: | 47 A for connection in the motor supply line for severe applications47 A for connection in the motor supply line for standard applications81 A for connection to the motor delta terminals for severe applications81 A for connection to the motor delta terminals for standard applications |
| Assembly style: | With heat sink |
|---|---|
| Function available: | External bypass (optional) |
| Supply frequency: | 50...60 Hz - 5...5 % |
| Network frequency: | 47.5...63 Hz |
| Device connection: | To the motor delta terminalsIn the motor supply line |
| Discrete output number: | 2 |
| Discrete output type: | (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO |
| Output absolute accuracy precision: | +/- 5 % |
| Minimum switching current: | 10 mA at 6 V DC for relay outputs |
| Maximum switching current: | Logic output 0.2 A at 30 V DCRelay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 msRelay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms |
| Discrete input number: | 5 |
| Discrete input type: | PTC, 750 Ohm at 25 °C (Stop, Run, LI3, LI4) logic, |
| Discrete input voltage: | 24 V |
| Discrete input logic: | Positive logic Stop, Run, LI3, LI4 at State 0: 11 V, >= 5 mA |
| Supply inrush current: | 0.4...1.3 Icl adjustable |
| Analogue output type: | Current output AO: 0-20 mA or 4-20 mA, impedance |
| Communication port protocol: | Modbus |
| Connector type: | 1 RJ45 |
| Communication data link: | Serial |
| Physical interface: | RS485 multidrop |
| Transmission rate: | 4800, 9600 or 19200 bps |
| Installed device: | 31 |
| Protection type: | Phase failure: lineThermal protection: motorThermal protection: starter |
| Marking: | CE |
| Operating position: | Vertical +/- 10 degree |
| Height: | 275 mm |
| Width: | 160 mm |
| Depth: | 190 mm |
| Product weight: | 4.9 kg |
| Power range: | 15...25 kW at 200...240 V 3 phases30...50 kW at 380...440 V 3 phases7...11 kW at 200...240 V 3 phases15...25 kW at 380...440 V 3 phases |
| Motor starter type: | Soft starter |
In short
Reference ATS48D47Q
Product Name soft starter for asynchronous motor - ATS48 - 42 A - 230..415 V - 9..45 KW - ATS48D47Q
Range Altistart 48
Related Categories