SCHNEIDER
Modular liquid level control relay, 8 A, 1 CO, 24…240 V AC/DC - RM22LG11MR
RM22LG11MR
€60.01 Excl. Tax
€72.01 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 25 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 100€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Range of product: | Harmony Control Relays |
---|---|
Product or component type: | Level control relay |
Relay type: | Level control relay |
Relay name: | RM22L |
Relay monitored parameters: | Detection by resistive probes |
Time delay type: | Without |
Switching capacity in VA: | 2000 VA |
Measurement range: | 5...100 kOhm |
Contacts type and composition: | 2 C/O |
Connections - terminals: | Screw connectors |
[Uc] control circuit voltage: | 24...240 V |
[In] rated current: | 8 A |
Reset time: | 1750 ms |
---|---|
Maximum switching voltage: | 250 V AC |
Minimum switching current: | 10 mA at 5 V DC |
Maximum switching current: | 8 A AC |
[Us] rated supply voltage: | 24...240 V AC/DC 50/60 Hz |
Supply voltage limits: | 20.4...264 V AC/DC |
Control circuit voltage limits: | - 15 % + 10 % Un |
Power consumption in VA: | 5 VA AC |
Maximum power consumption in W: | 1.5 W DC |
Output contacts: | 2 C/O |
Nominal output current: | 8 A |
Run-up delay at power-up: | 0.6 s |
Maximum electrode voltage: | 12 V AC |
Maximum electrode current: | 1 mA |
Repeat accuracy: | +/- 2 % for time delay |
Measurement error: | 0.05 %/°C with temperature variation |
Sensitivity scale: | 5...100 kOhm St (Standard Sensitivity) |
Sensitivity adjustment: | 5...100 % |
Maximum supply current for sensors: | 1 mA |
Maximum cable distance between devices: | 1000 m between probe and delay |
Cable capacitance: | 1 nF at HS (High Sensitivity) for probe cable2.2 nF at St (Standard Sensitivity) for probe cable4.7 nF at LS (Low Sensitivity) for probe cable |
Overvoltage category: | III conforming to IEC 60664-1 |
Insulation resistance: | > 100 MOhm at 500 V DC conforming to IEC 60255-27 |
Insulation: | Between supply and measurement |
Mounting position: | Any position |
Connections - terminals: | Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable endScrew terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable endScrew terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable endScrew terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end |
Tightening torque: | 0.6...1 N.m conforming to IEC 60947-1 |
Housing material: | Self-extinguishing plastic |
Status LED: | LED (yellow)relay ONLED (green)power ON |
Mounting support: | 35 mm DIN rail conforming to EN/IEC 60715 |
Electrical durability: | 100000 cycles |
Mechanical durability: | 10000000 cycles |
Utilisation category: | AC-15 conforming to IEC 60947-5-1DC-13 conforming to IEC 60947-5-1AC-1 conforming to IEC 60947-4-1DC-1 conforming to IEC 60947-4-1 |
Safety reliability data: | B10d = 120000MTTFd = 125.5 years |
Contacts material: | Cadmium free |
Width: | 22.5 mm |
Product weight: | 0.1 kg |
Functionality: | Resistive probe detection |
Compatibility code: | RM22 |
Immunity to microbreaks: | 100 ms DC90 ms AC |
---|---|
Electromagnetic compatibility: | Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1Immunity for industrial environments conforming to EN/IEC 61000-6-2Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3Emission standard for industrial environments conforming to EN/IEC 61000-6-4Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5Conducted and radiated emissions class B group 1 conforming to CISPR 11Conducted and radiated emissions class B conforming to CISPR 22 |
Standards: | EN/IEC 60255-1 |
Product certifications: | GLRCMCCCCSAULEACCE |
Ambient air temperature for storage: | -40...70 °C |
Ambient air temperature for operation: | -20...50 °C at 60 Hz-20...60 °C at 50 Hz AC/DC |
Relative humidity: | 93...97 % at 25...55 °C conforming to IEC 60068-2-30 |
Vibration resistance: | 0.075 mm (f= 10...58.1 Hz) not in operation conforming to IEC 60068-2-61 gn (f= 10...58.1 Hz) not in operation conforming to IEC 60068-2-60.035 mm (f= 58.1...150 Hz) in operation conforming to IEC 60068-2-60.5 gn (f= 58.1...150 Hz) in operation conforming to IEC 60068-2-6 |
Shock resistance: | 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-275 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27 |
IP degree of protection: | IP20 (terminals) conforming to IEC 60529IP40 (housing) conforming to IEC 60529IP50 (front panel) conforming to IEC 60529 |
Pollution degree: | 3 conforming to IEC 60664-1 |
Dielectric test voltage: | 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27 |
Sustainable offer status: | Green Premium productREACh Regulation |
Code EAN: | 3606480792328 |
---|
Brief
Reference RM22LG11MR
Product Name Modular liquid level control relay, 8 A, 1 CO, 24…240 V AC/DC - RM22LG11MR
Our customers also bought
Recently Viewed Products
Related Categories