Utilisation category: | AC-15DC-13AC-14 |
---|
Pole contact composition: | 5 NO |
---|
[Ue] rated operational voltage: | |
---|
Control circuit type: | AC at 50/60 Hz |
---|
[Uc] control circuit voltage: | 24 V AC 50/60 Hz |
---|
[Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947 |
---|
[Ith] conventional free air thermal current: | 10 A (at 60 °C) |
---|
Irms rated making capacity: | 140 A AC conforming to IEC 60947-5-1250 A DC conforming to IEC 60947-5-1 |
---|
[Icw] rated short-time withstand current: | 100 A - 1 s120 A - 500 ms140 A - 100 ms |
---|
Associated fuse rating: | 10 A gG conforming to IEC 60947-5-1 |
---|
[Ui] rated insulation voltage: | 600 V UL certified600 V CSA certified690 V conforming to IEC 60947-5-1 |
---|
Mounting support: | RailPlate |
---|
Connections - terminals: | Screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable endScrew clamp terminals 2 cable(s) 1...4 mm²flexible without cable endScrew clamp terminals 1 cable(s) 1...4 mm²flexible with cable endScrew clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable endScrew clamp terminals 1 cable(s) 1...4 mm²solid without cable endScrew clamp terminals 2 cable(s) 1...4 mm²solid without cable end |
---|
Tightening torque: | 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 21.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
---|
Control circuit voltage limits: | 0.3...0.6 Uc (-40...70 °C):drop-out AC 50/60 Hz0.8...1.1 Uc (-40...60 °C):operational AC 50 Hz0.85...1.1 Uc (-40...60 °C):operational AC 60 Hz1...1.1 Uc (60...70 °C):operational AC 50/60 Hz |
---|
Operating time: | 12...22 ms coil energisation and NO closing4...12 ms coil de-energisation and NO opening |
---|
Mechanical durability: | 30 Mcycles |
---|
Maximum operating rate: | 180 cyc/mn |
---|
Inrush power in VA: | 70 VA 50 Hz (at 20 °C) |
---|
Hold-in power consumption in VA: | 8 VA 50 Hz (at 20 °C) |
---|
Minimum switching voltage: | 17 V |
---|
Minimum switching current: | 5 mA |
---|
Non-overlap time: | 1.5 ms on energisation between NC and NO contact1.5 ms on de-energisation between NC and NO contact |
---|
Insulation resistance: | > 10 MOhm |
---|
Mechanical robustness: | Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27Vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6Vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
---|
Height: | 77 mm |
---|
Width: | 45 mm |
---|
Depth: | 84 mm |
---|
Product weight: | 0.58 kg |
---|
Compatibility code: | CAD |
---|