9,3/10 out of 1126 reviews
SCHNEIDER

module XPSAV - Emergency stop - 24 V DC, time delay 0...300 s - XPSAV11113

XPSAV11113

Obsolete product, here is the proposed substitution for the reference XPSAV11113 : XPSUAT13A3AP
Technical informations
Range of product: Preventa Safety automation
Product or component type: Preventa safety module
Safety module name: XPSAV
Safety module application: For emergency stop and switch monitoring
Function of module: Emergency stop button with 2 NC contacts, monitored startEmergency stop monitoring 2-channel wiringMonitoring of a movable guard associated with 2 switches automatic startEmergency stop button with 1 NC contact, automatic start or unmonitored startEmergency stop monitoring 1-channel wiring
Safety level: Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
Safety reliability data: DC > 99 % conforming to EN/ISO 13849-1MTTFd = 75.8 years conforming to EN/ISO 13849-1PFHd = 7.95E-9 1/h conforming to EN/IEC 62061
Type of start: Configurable
Connections - terminals: Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezelCaptive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Output type: Relay instantaneous opening, 3 NO circuit(s), volt-freeRelay time delay opening, 3 NO circuit(s), volt-free
Number of additional circuits: 3 solid state outputs
[Us] rated supply voltage: 24 V DC - 20...20 %
Synchronisation time between inputs: 1.5 s for guardUnlimited for emergency stop
Maximum power consumption in W: 5 W DC
Input protection type: Internal, electronic
Time delay range: 0...300 s
[Uc] control circuit voltage: 24 V DC
Maximum line resistance: 100 Ohm
Breaking capacity: 180 VA holding AC-15 C300 relay output1800 VA inrush AC-15 C300 relay output
Breaking capacity: 20 mA at 24 V1.25 A at 24 V (DC-13) time constant: 50 ms for relay output
Output thermal current: 2 A for 1 output and 4 A for the other 2 outputs for instantaneous and time delay outputs3.3 A for all 3 outputs for instantaneous and time delay outputs6 A for 1 output and 2 A for the other 2 outputs for instantaneous and time delay outputs
[Ith] conventional free air thermal current: 20 A
Associated fuse rating: 4 A gG or gL for instantaneous and time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 2006 A fast blow conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Minimum output current: 10 mA for relay output
Minimum output voltage: 17 V for relay output
Maximum response time on input open: 30 ms
[Ui] rated insulation voltage: 300 V (pollution degree 2) conforming to IEC 60947-5-1300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
[Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to IEC 60947-5-14 kV overvoltage category III conforming to DIN VDE 0110 part 1
Local signalling: 11 LEDs
Mounting support: 35 mm symmetrical DIN rail
Product weight: 0.32 kg