Technical informations
| Range: | Acti9 |
|---|---|
| Product name: | Acti9 iCV40 |
| Product or component type: | Residual current breaker with overcurrent protection (RCBO) |
| Device short name: | iCV40N |
| Device application: | Distribution |
| Poles description: | 1P + N |
| Number of protected poles: | 1 |
| Neutral position: | Left |
| [In] rated current: | 32 A |
| Network type: | AC |
| Trip unit technology: | Thermal-magnetic |
| Curve code: | C |
| Earth-leakage sensitivity: | 30 mA |
| Earth-leakage protection time delay: | Instantaneous |
| Earth-leakage protection class: | Type A |
| Breaking capacity: | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 |
| Suitability for isolation: | Yes conforming to EN/IEC 60947-2 |
| Quality labels: | EACRCMOVEKEMA-KEURVDE |
| Device location in system: | Outgoer |
|---|---|
| Network frequency: | 50/60 Hz |
| [Ue] rated operational voltage: | 230 V AC 50/60 Hz |
| Magnetic tripping limit: | 5...10 x In |
| Residual current tripping technology: | Voltage independent |
| [Ics] rated service breaking capacity: | 6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 |
| Rated breaking and making capacity: | Idm 6000 A at 230 V AC 50/60 Hz conforming to EN 61009-2-1Idm 500 A at 230 V AC 50/60 Hz conforming to IEC 61009-2-1 |
| Limitation class: | 3 conforming to EN/IEC 61009-2-1 |
| [Ui] rated insulation voltage: | 400 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage: | 4 kV |
| Contact position indicator: | Yes |
| Control type: | Toggle |
| Local signalling: | Fault indicationON/OFF indication |
| Mounting mode: | Clip-on |
| Mounting support: | DIN rail |
| Comb busbar and distribution block compatibility: | Top or bottom: tooth |
| Connection pitch: | 9 mm between phase and neutral |
| 9 mm pitches: | 4 |
| Height: | 85 mm |
| Width: | 36 mm |
| Depth: | 73 mm |
| Net weight: | 210 g |
| Colour: | White |
| Mechanical durability: | 20000 cycles |
| Electrical durability: | 10000 cycles |
| Locking options description: | SealablePadlocking device |
| Connections - terminals: | Tunnel type terminals top or bottom 1...16 mm² rigidTunnel type terminals top or bottom 1...10 mm² flexible |
| Wire stripping length: | 14 mm for top or bottom connection |
| Tightening torque: | 2 N.m top or bottom |
| Earth-leakage protection: | Integrated |
| Compatibility code: | ICV40N |