calcActive())">
SCHNEIDER
remote controlled source changeover, Transferpact, ACP plate and BA controller, 220 VAC to 240 VAC 50/60 Hz - 29470
29470
€1,555.49 Excl. Tax
€1,866.59 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process - Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 250€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
| Range of product: | MasterPact NTNSX100...250Compact NS100...630MasterPact NWCompact NS630b...1600NSX400...630 |
|---|---|
| Product or component type: | Interface and control unit |
| Accessory / separate part category: | Interlocking accessory |
| Range compatibility: | ComPact NS circuit breakerComPact NSX circuit breakerMasterPact NT circuit breakerMasterPact NW circuit breaker |
| Device short name: | ACP + BA |
| [Us] rated supply voltage: | 220...240 V AC at 50/60 Hz |
| Operating mode: | Automatic operationForced operation on replacement sourceForced operation on normal sourceStop (both normal and replacement source off) |
|---|---|
| Interlocked device: | NSX400...630MasterPact NWNSX100...250MasterPact NTCompact NS630b...1600Compact NS100...630 |
| Selection modes: | Circuit breaker on NCircuit breaker on R |
| Test function: | By opening the P25M circuit breaker supplying the controller |
| Complementary function: | Additional contact: transfer to replacement source only if contact is closedVoluntary transfer to replacement source (e.g. energy management commands) |
| Local signalling: | OffOnFault trip |
| Input type: | Contacts customer voluntary order to transfer to source R |
| Output type: | Contacts customer: indication of operation in automatic or stop mode |
| [Ith] conventional free air thermal current: | 8 A |
| [Ie] rated operational current: | AC-12: 4 A AC 440 VAC-12: 5 A AC 380/415 VAC-12: 8 A AC 110 VAC-12: 8 A AC 220/240 VAC-12: 8 A AC 24 VAC-12: 8 A AC 48 VAC-13: 6 A AC 110 VAC-13: 6 A AC 220/240 VAC-13: 7 A AC 24 VAC-13: 7 A AC 48 VAC-14: 4 A AC 110 VAC-14: 4 A AC 220/240 VAC-14: 5 A AC 24 VAC-14: 5 A AC 48 VAC-15: 3 A AC 220/240 VAC-15: 4 A AC 110 VAC-15: 5 A AC 24 VAC-15: 5 A AC 48 VDC-12: 0.4 A DC 250 VDC-12: 0.6 A DC 110 VDC-12: 2 A DC 48 VDC-12: 8 A DC 24 VDC-13: 2 A 24 V |
| Product compatibility: | Compact NS630b...1600Compact NSX100...250Compact NSX400...630 |
| Compatibility code: | ACP+BA |
In short
Reference 29470
Product Name remote controlled source changeover, Transferpact, ACP plate and BA controller, 220 VAC to 240 VAC 50/60 Hz - 29470
Related Categories