calcActive())">
SCHNEIDER
remote control source changeover, Transferpact, ACP plate and UA controller, 380 VAC to 415 VAC 50/60 Hz, 440 VAC 60 Hz - 29473
29473
€1,153.01 Excl. Tax
€1,383.61 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 250€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
| Range of product: | NSX100...250NSX400...630MasterPact NTCompact NS100...630Compact NS630b...1600MasterPact NW |
|---|---|
| Product or component type: | Interface and control unit |
| Accessory / separate part category: | Interlocking accessory |
| Range compatibility: | ComPact NS circuit breakerComPact NSX circuit breakerMasterPact NT circuit breakerMasterPact NW circuit breaker |
| Device short name: | ACP + UA |
| [Us] rated supply voltage: | 380...415 V AC at 50/60 Hz440 V AC at 60 Hz |
| Operating mode: | Forced operation on replacement sourceStop (both normal and replacement source off)Automatic operationForced operation on normal source |
|---|---|
| Interlocked device: | MasterPact NWNSX400...630NSX100...250Compact NS100...630MasterPact NTCompact NS630b...1600 |
| Selection modes: | Circuit breaker on RCircuit breaker on N |
| Test function: | By pressing the test button on the front of the controller |
| Complementary function: | Additional contact: transfer to replacement source only if contact is closedSetting of maximum startup time for the replacement sourceForced normal source if replacement source not operational during peak-tariffSelection of type of normal source (single-phase or three-phase)Voluntary transfer to replacement source (e.g. energy management commands) |
| Local signalling: | OffFault tripOn |
| Input type: | Contacts customer voluntary order to transfer to source R |
| Output type: | Contacts customer: indication of operation in automatic or stop mode |
| [Ith] conventional free air thermal current: | 8 A |
| [Ie] rated operational current: | AC-12: 4 A AC 440 VAC-12: 5 A AC 380/415 VAC-12: 8 A AC 110 VAC-12: 8 A AC 220/240 VAC-12: 8 A AC 24 VAC-12: 8 A AC 48 VAC-13: 6 A AC 110 VAC-13: 6 A AC 220/240 VAC-13: 7 A AC 24 VAC-13: 7 A AC 48 VAC-14: 4 A AC 110 VAC-14: 4 A AC 220/240 VAC-14: 5 A AC 24 VAC-14: 5 A AC 48 VAC-15: 3 A AC 220/240 VAC-15: 4 A AC 110 VAC-15: 5 A AC 24 VAC-15: 5 A AC 48 VDC-12: 0.4 A DC 250 VDC-12: 0.6 A DC 110 VDC-12: 2 A DC 48 VDC-12: 8 A DC 24 VDC-13: 2 A 24 V |
| Product compatibility: | Compact NSX100...250Compact NS630b...1600Compact NSX400...630 |
| Compatibility code: | ACP+UA |
In short
Reference 29473
Product Name remote control source changeover, Transferpact, ACP plate and UA controller, 380 VAC to 415 VAC 50/60 Hz, 440 VAC 60 Hz - 29473
Related Categories