Technical informations
| Range of product: | RED |
|---|---|
| Range: | Acti 9 |
| Product or component type: | Residual current circuit breaker (RCCB) |
| Device short name: | REDs |
| Protection type: | Recloser |
| Poles description: | 4P |
| Neutral position: | Left |
| Signal contacts composition: | 1NO or 1NC or intermittent 1 Hz |
| [In] rated current: | 40 A |
| Earthing system: | TN-STT |
| Network type: | AC |
| Earth-leakage sensitivity: | 300 mA |
| Device location in system: | Outgoer |
|---|---|
| Network frequency: | 50 Hz |
| [Ue] rated operational voltage: | 400 V AC 50 Hz phase to neutral |
| Reset: | Fault reset earth leakage |
| Test function: | Manual at > 170 V |
| Earth-leakage protection time delay: | Instantaneous |
| Earth-leakage protection class: | Type A |
| Minimum leakage resistance: | 5 kOhm at operating2.5 kOhm at non-operating |
| [Im] rated making and breaking capacity: | Idm 630 A 400 V |
| Rated conditional short-circuit current: | Inc: 15 kA - associated with iC60H, 25 AInc: 6 kA - associated with DPN, 40 AInc: 10 kA - associated with gG fuse, 40 AInc: 15 kA - associated with iC60L, 25 AInc: 15 kA - associated with NG125, 25 AInc: 15 kA - associated with gG fuse, 25 AInc: 10 kA - associated with DPNN, 40 AInc: 10 kA - associated with iC60H, 40 AInc: 10 kA - associated with iC60L, 40 AInc: 10 kA - associated with NG125, 40 AInc: 10 kA - associated with iC60N, 40 A |
| [Ui] rated insulation voltage: | 500 V |
| [Uimp] rated impulse withstand voltage: | 4 kV |
| Surge current: | 250 A |
| Control type: | Toggle |
| Local signalling: | 2 LEDsResidual current device |
| Operating mode: | Reclosing time: Max nb of consecutive restart: 3Min interval between 2 closings: 30 sStopping restart cycle if insulation fault present: 15 minInsulation fault presence monitoring |
| Insulation fault diagnosis: | If fault detected, diagnosis every 2 minutes |
| Signalling circuit voltage: | AC: 5...230 VDC: 5...230 V |
| Signalling output current: | 0.6 mA min100 mA max, cos phi =1 |
| Mounting mode: | Fixed |
| Mounting support: | 35 mm symmetrical DIN rail |
| 9 mm pitches: | 14 |
| Height: | 98 mm |
| Width: | 125 mm |
| Depth: | 79.5 mm |
| Embedding depth: | 73.5 mm |
| Product weight: | 0.67 kg |
| Mechanical durability: | 4000 cycles open-close |
| Connections - terminals: | Guard tunnel terminal 35 mm² rigidGuard tunnel terminal 35 mm² flexibleGuard tunnel terminal 35 mm² flexible with ferrule |
| Auxiliary connection terminal: | Tunnel type terminal in 2.5 mm² flexibleTunnel type terminal in 2.5 mm² rigidTunnel type terminal in 2.5 mm² flexible with ferrule |
| Wire stripping length: | Power circuit: 12 mmSignaling: 9 mm |
| Tightening torque: | Power circuit: 2 N.mSignaling: 0.4 N.m |
| Market segment: | Small commercial |
| Compatibility code: | REDs |