Technical informations
| Range: | TeSys |
|---|---|
| Range of product: | TeSys U |
| Product name: | TeSys U |
| Device short name: | LUCM |
| Product or component type: | Multifunction control unit |
| Device application: | Motor controlMotor protection |
| Product specific application: | Most sophisticated control and protection requirements, with display |
| Function available: | Manual or automatic resetMonitoring function, indication of main motor parametersOverload, no-load runningProtection function alarmProtection against overload and short-circuitProtection against phase failure and phase imbalanceEarth fault protectionLog functionDifferentiation of thermal overload and magnetic fault |
| Product compatibility: | Power base LUB32Power base LUB38Power base LUB320Power base LUB380Reversing contactor breaker LU2B32FUReversing contactor breaker LU2B38FU |
| [Ue] rated operational voltage: | 690 V AC |
| Network frequency: | 40...60 Hz |
| Load type: | 3-phase motor - cooling: self-cooled - setting factory setting3-phase motor - cooling: self-cooled, force cooled - setting settableSingle-phase motor - cooling: self-cooled, force cooled - setting settable |
| Utilisation category: | AC-43AC-41AC-44 |
| Motor power kW: | 15Â kW at 400...440 V AC 50/60 Hz for 3 phases motors15Â kW at 500 V AC 50/60 Hz for 3 phases motors18.5Â kW at 690 V AC 50/60 Hz for 3 phases motors7.5Â kW at 400...440 V AC 50/60 Hz for 1 phase motors |
| Thermal protection adjustment range: | 8...32Â A |
| Thermal overload class: | Class 5...30 - frequency limit: 50...60 Hz - temperature compensation: -25...55 °C conforming to IEC 60947-6-2Class 5...30 - frequency limit: 50...60 Hz - temperature compensation: -25...55 °C conforming to UL 508 |
| Tripping threshold: | 14.2 x Ir +/- 20 % |
| [Uc] control circuit voltage: | 24 V DC |
| Control circuit voltage limits: | 20...28 V for DC circuit 24 V in operation14.5 V for DC circuit 24 V drop-out |
|---|---|
| Typical current consumption: | 220Â mA at 24 V DC I maximum while closing with LUB32220Â mA at 24 V DC I maximum while closing with LUB3880Â mA at 24 V DC I rms sealed with LUB3280Â mA at 24 V DC I rms sealed with LUB38 |
| Heat dissipation: | 1.8Â W for control circuit with LUB321.8Â W for control circuit with LUB380.8Â W for external auxiliary circuit |
| Operating time: | 35 ms opening with LUB32 for control circuit35 ms opening with LUB38 for control circuit65 ms closing with LUB32 for control circuit65 ms closing with LUB38 for control circuit |
| Physical interface: | RS485 multidrop - connector(s): RJ45 - location: front panel - communication protocol: Modbus RTU 19200 bit/s |
| Return time: | |
| Messages display capacity: | 2 lines of 12 characters - display LCD - English - accuracy +/- 5 % - resolution 1 % of Ir2 lines of 12 characters - display LCD - French - accuracy +/- 5 % - resolution 1 % of Ir2 lines of 12 characters - display LCD - German - accuracy +/- 5 % - resolution 1 % of Ir2 lines of 12 characters - display LCD - Italian - accuracy +/- 5 % - resolution 1 % of Ir2 lines of 12 characters - display LCD - Spanish - accuracy +/- 5 % - resolution 1 % of Ir |
| Reset: | Automatic reset - setting: setting rangeManual - setting: factory settingManual - setting: setting rangeRemote reset - setting: setting range |
| Time before reset: | 1...1000Â s - reset manual or automatic reset - setting settable120Â s - reset manual - setting factory setting |
| User language: | English - setting factory settingEnglish, French, German, Italian, Spanish - setting settable |
| Information displayed: | Average current (factory setting)Average current (settable)Cause of last 5 faults (settable)Current in phase (settable)Earth leakage current (settable)Phase imbalance (settable)Thermal state of motor (settable) |
| Standards: | EN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase barrierCSA C22.2 No 60947-4-1, with phase barrier |
| Product certifications: | CEULCSACCCEACASEFAATEXMarine |
| [Ui] rated insulation voltage: | 690Â V conforming to IEC 60947-6-2600Â V conforming to UL 60947-4-1600Â V conforming to CSA C22.2 No 60947-4-1 |
| [Uimp] rated impulse withstand voltage: | 6Â kV conforming to IEC 60947-6-2 |
| Safe separation of circuit: | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 |
| Fixing mode: | Plug-in (front face) |
| Width: | 45Â mm |
| Height: | 66Â mm |
| Depth: | 60Â mm |
| Product weight: | 0.175Â kg |
| Compatibility code: | LUCM |