Technical informations
| Range: | TeSysTeSys Deca |
|---|---|
| Range of product: | TeSys GV2 |
| Product name: | TeSys GV2TeSys Deca |
| Product or component type: | Circuit breaker |
| Device short name: | GV2ME |
| Device application: | Motor |
| Trip unit technology: | Thermal-magnetic |
| Poles description: | 3P |
|---|---|
| Network type: | AC |
| Utilisation category: | AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2 |
| Network frequency: | 50/60 Hz conforming to IEC 60947-4-1 |
| Fixing mode: | 35 mm symmetrical DIN rail: clippedPanel: screwed (with adaptor plate) |
| Operating position: | Any position |
| Motor power kW: | 0.37 kW at 400/415 V AC 50/60 Hz0.37 kW at 500 V AC 50/60 Hz0.55 kW at 400/415 V AC 50/60 Hz0.55 kW at 500 V AC 50/60 Hz0.75 kW at 500 V AC 50/60 Hz |
| Breaking capacity: | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity: | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| Control type: | Push-button |
| [In] rated current: | 1.6 A |
| Trip unit rating: | 1...1.6 A |
| Magnetic tripping current: | 22.5 A |
| [Ue] rated operational voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ith] conventional free air thermal current: | 1.6 A conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947-2 |
| Power dissipation per pole: | 2.5 W |
| Mechanical durability: | 100000 cycles |
| Electrical durability: | 100000 cycles for AC-3 at 440 V |
| Maximum operating rate: | 25 cyc/h |
| Rated duty: | Continuous conforming to IEC 60947-4-1 |
| Direct connector: | Without |
| Suitability for isolation: | Yes conforming to IEC 60947-1 |
| Phase failure sensitivity: | Yes conforming to IEC 60947-4-1 |
| Height: | 101 mm |
| Width: | 45 mm |
| Depth: | 78.5 mm |
| Product weight: | 0.28 kg |
| Colour: | Dark grey |
| Compatibility code: | GV2ME |
In short
Reference GV2ME063
Product Name TeSys GV2ME - motor circuit breaker - 1..1,6A - 3P 3d - magneto-thermal release - GV2ME063
Range TeSys
Device function Moteur