Technical informations
| Range: | TeSys |
|---|---|
| Range of product: | TeSys GV2 |
| Product name: | TeSys GV2 |
| Product or component type: | Circuit breaker |
| Device short name: | GV2LE |
| Device application: | Motor |
| Poles description: | 3P |
| Network type: | AC |
| Utilisation category: | Category A conforming to IEC 60947-2AC-3 conforming to IEC 60947-4-1 |
| Network frequency: | 50/60 Hz conforming to IEC 60947-2 |
| Breaking capacity: | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity: | 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit technology: | Magnetic |
| Magnetic tripping current: | 8 A |
| Fixing mode: | 35 mm symmetrical DIN rail: clippedPanel: screwed (with adaptor plate) |
|---|---|
| Operating position: | Any position |
| Motor power kW: | 0.12 kW at 400/415 V AC 50/60 Hz0.18 kW at 400/415 V AC 50/60 Hz0.37 kW at 690 V AC 50/60 Hz |
| Control type: | Toggle |
| [In] rated current: | 0.63 A |
| [Ue] rated operational voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage: | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage: | 6 kV conforming to IEC 60947-2 |
| Power dissipation per pole: | 1.8 W |
| Mechanical durability: | 100000 cycles |
| Electrical durability: | 100000 cycles for AC-3 at 415 V |
| Maximum operating rate: | 40 cyc/h |
| Rated duty: | Continuous conforming to IEC 60947-4-1 |
| Direct connector: | Without |
| Connections - terminals: | Screw clamp terminals 2 cable(s) 1...6 mm² solidScrew clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable endScrew clamp terminals 2 cable(s) 1...4 mm² flexible with cable end |
| Tightening torque: | 1.7 N.m on screw clamp terminals |
| Mechanical robustness: | Shocks: 30 Gn conforming to IEC 60068-2-27Vibrations: 5 Gn, 5...150 Hz conforming to IEC 60068-2-6 |
| Suitability for isolation: | Yes conforming to IEC 60947-1 |
| Height: | 89 mm |
| Width: | 45 mm |
| Depth: | 78.5 mm |
| Product weight: | 0.33 kg |
| Compatibility code: | GV2LE |