

calcActive())">
ABB
Motor circuit breaker Series MS132 10 - 16A - ABB1SAM350000R1011
ABB1SAM350000R1011
€55.00 Excl. Tax
€66.00 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 250€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
| Product Net Width: | 45 mm |
|---|---|
| Product Net Height: | 97,8 mm |
| Product Net Depth / Length: | 86,55 mm |
| Product Net Weight: | 0.31 kg |
| Rated service short-circuit breaking capacity (Ics): | (230 V AC) 100 kA - (250 V DC) 3 poles in series 10 kA - (400 V AC) 100 kA - (440 V AC) 30 kA - (500 V AC) 10 kA - (690 V AC) 3 kA |
|---|---|
| Rated ultimate short-circuit breaking capacity (Icu): | (230 V AC) 100 kA - (400 V AC) 100 kA - (440 V AC) 30 kA - (500 V AC) 10 kA - (690 V AC) 3 kA |
| Rated instantaneous short-circuit current setting (Ii): | 240 A |
| Setting range: | 10 ... 16 A |
| Rated operational power AC-3 (Pe): | (400 V) Three-phase 7,5 kW |
| Rated operational power AC-3e (Pe): | (400 V) Three-phase 7,5 kW |
| Rated operational voltage: | Main circuit 690 V AC - Main circuit 250 V DC |
| Rated operational current (Ie): | 16 A |
| Rated operational current AC-3 (Ie): | 16 A |
| Rated operational current AC-3e (Ie): | 16 A |
| Rated operational current DC-5 (Ie): | 16 A |
| Rated frequency (f): | Main circuit 50 Hz - Main circuit 60 Hz |
| Operating frequency (fsw): | 0 ... 400 Hz |
| Rated impulse withstand voltage (Uimp): | Main circuit 6 kV |
| Rated insulation voltage (Ui): | 690 V |
| Power loss: | at rated operating conditions per pole 1.1 ... 2,8 W |
| Number of poles: | 3P |
| Conventional free-air thermal current (Ith): | Main circuit 16 A |
| Degree of protection: | Housing IP20 - Main circuit terminals IP10 |
| Pollution degree: | 3 |
| Electrical durability: | 50000 cycles |
| Mechanical durability: | Number of operations 100000 cycles |
| Terminal type: | Screw terminals |
| Connecting capacity main circuit: | Flexible with ferrule 1/2x 0.75 ... 6 mm² - Flexible with insulated ferrule 1/2x 0.75 ... 6 mm² - Flexible 1/2x 1 ... 2.5 mm² - Flexible 1/2x 2.5 ... 6 mm² - Rigid 1/2x 1 ... 2.5 mm² - Rigid 1/2x 2.5 ... 6 mm² |
| Tightening torque: | Main circuit 2 N·m |
| Wire stripping length: | Main circuit 10 mm |
| Recommended screw driver: | Pozidriv 2 |
| Mounting position: | 1 ... 6 |
| Mounting on DIN rail: | TH35-15 (35 x 15 mm mounting rail) acc. to IEC 60715 - TH35-7.5 (35 x 7.5 mm mounting rail) acc. to IEC 60715 - Minimum mounting distance |
| Contact position indication: | ON / OFF / TRIP |
| Standards: | IEC/EN 60947-1 - IEC/EN 60947-2 - IEC/EN 60947-4-1 - UL 60947-1 - UL 60947-4-1 - IEC 60335-2-40 A2L |
| Remarks: | UL508 Self-protected combination motor controller (Type E) in combination with feeder block S1-M3-xx- |
In short
Reference ABB1SAM350000R1011
Product Name Motor circuit breaker Series MS132 10 - 16A - ABB1SAM350000R1011
Related Categories
