Technical informations
| Device application: | Distribution |
|---|---|
| Range: | Acti 9 |
| Range of product: | IC60 |
| Product name: | Acti 9 iC60 |
| Product or component type: | Miniature circuit-breaker |
| Device short name: | IC60N |
| Poles description: | 1P |
| Number of protected poles: | 1 |
| [In] rated current: | 4 A |
| Network type: | DCAC |
| Trip unit technology: | Thermal-magnetic |
| Curve code: | C |
| Breaking capacity code: | N |
| Breaking capacity: | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-150 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-250 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-250 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-210 kA Icu at 60...72 V DC conforming to EN/IEC 60947-215 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 |
| Utilisation category: | Category A conforming to EN 60947-2Category A conforming to IEC 60947-2 |
| Suitability for isolation: | Yes conforming to EN 60898-1Yes conforming to EN 60947-2Yes conforming to IEC 60898-1Yes conforming to IEC 60947-2 |
| Standards: | EN 60898-1IEC 60947-2IEC 60898-1EN 60947-2 |
| Quality labels: | NF |
| Network frequency: | 50/60 Hz |
|---|---|
| [Ue] rated operational voltage: | 230 V AC 50/60 Hz12...60 V AC 50/60 Hz220...240 V AC 50/60 Hz100...133 V AC 50/60 Hz72 V DC12...60 V DC |
| Magnetic tripping limit: | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity: | 50 kA 100 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz50 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz50 kA 100 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz50 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz50 kA 100 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz50 kA 100 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz10 kA 100 % conforming to EN 60947-2 - 72 V DC10 kA 100 % conforming to IEC 60947-2 - 72 V DC15 kA 100 % conforming to EN 60947-2 - 12...60 V DC15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC |
| Limitation class: | 3 conforming to EN 60898-13 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage: | 500 V AC 50/60 Hz conforming to EN 60947-2500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage: | 6 kV conforming to EN 60947-26 kV conforming to IEC 60947-2 |
| Contact position indicator: | Yes |
| Control type: | Toggle |
| Local signalling: | Trip indicator |
| Mounting mode: | Fixed |
| Mounting support: | DIN rail |
| Comb busbar and distribution block compatibility: | Top or bottom: YES |
| 9 mm pitches: | 2 |
| Height: | 85 mm |
| Width: | 18 mm |
| Depth: | 78.5 mm |
| Product weight: | 0.215 kg |
| Colour: | White |
| Mechanical durability: | 20000 cycles |
| Electrical durability: | 10000 cycles |
| Connections - terminals: | Single terminal (top or bottom) 1...25 mm² rigidSingle terminal (top or bottom) 1...16 mm² flexible |
| Wire stripping length: | 14 mm for top or bottom connection |
| Tightening torque: | 2 N.m top or bottom |
| Earth-leakage protection: | Without |
| Compatibility code: | IC60 |
| Market segment: | Small commercial |