calcActive())">
SCHNEIDER
Miniature circuit-breaker, Acti9 iC60H, 2P, 6 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) - A9F07206
A9F07206
This product is no longer available. Contact us for a suitable replacement solution tailored to your needs.
Technical informations
| Device application: | Distribution |
|---|---|
| Range: | Acti 9 |
| Range of product: | IC60 |
| Product name: | Acti 9 iC60 |
| Product or component type: | Miniature circuit-breaker |
| Device short name: | IC60H |
| Poles description: | 2P |
| Number of protected poles: | 2 |
| [In] rated current: | 6Â A |
| Network type: | DCAC |
| Trip unit technology: | Thermal-magnetic |
| Curve code: | C |
| Breaking capacity code: | H |
| Breaking capacity: | 10000Â A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-142Â kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-210Â kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-215Â kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-230Â kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-215Â kA Icu at 42Â kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Utilisation category: | Category A conforming to EN 60898-1Category A conforming to IEC 60898-1 |
| Suitability for isolation: | Yes conforming to EN 60898-1Yes conforming to EN 60947-2Yes conforming to IEC 60898-1Yes conforming to IEC 60947-2 |
| Standards: | EN 60898-1IEC 60898-1IEC 60947-2EN 60947-2 |
| Network frequency: | 50/60 Hz |
|---|---|
| [Ue] rated operational voltage: | 220...240 V AC 50/60 Hz400 V AC 50/60 Hz380...415 V AC 50/60 Hz440 V AC 50/60 Hz12...133 V AC 50/60 Hz72...125 V DC |
| Magnetic tripping limit: | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity: | 15Â kA 50Â % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz7.5Â kA 50Â % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz5Â kA 50Â % conforming to EN 60947-2 - 440 V AC 50/60 Hz15Â kA 50Â % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz7.5Â kA 50Â % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz5Â kA 50Â % conforming to IEC 60947-2 - 440 V AC 50/60 Hz7500Â A 75Â % conforming to EN 60898-1 - 400 V AC 50/60 Hz7500Â A 75Â % conforming to IEC 60898-1 - 400 V AC 50/60 Hz21Â kA 50Â % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz21Â kA 50Â % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz15Â kA 100Â % conforming to IEC 60947-2 - 72...125 V DC15Â kA 100Â % conforming to EN 60947-2 - 72...125 V DC |
| Limitation class: | 3 conforming to EN 60898-13 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage: | 500Â V AC 50/60 Hz conforming to EN 60947-2500Â V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage: | 6Â kV conforming to EN 60947-26Â kV conforming to IEC 60947-2 |
| Contact position indicator: | Yes |
| Control type: | Toggle |
| Local signalling: | Trip indicator |
| Mounting support: | DIN rail |
| 9 mm pitches: | 4 |
| Height: | 91Â mm |
| Width: | 36Â mm |
| Depth: | 78.5Â mm |
| Product weight: | 0.25Â kg |
| Colour: | White |
| Mechanical durability: | 20000Â cycles |
| Electrical durability: | 10000Â cycles |
| Connections - terminals: | Double terminal (top or bottom) 1...25 mm² rigidDouble terminal (top or bottom) 1...16 mm² flexible |
| Wire stripping length: | 14Â mm for top or bottom connection |
| Tightening torque: | 2Â N.m top or bottom |
| Earth-leakage protection: | Separate block |
| Compatibility code: | IC60 |
| Market segment: | ResidentialSmall commercial |
In short
Reference A9F07206
Product Name Miniature circuit-breaker, Acti9 iC60H, 2P, 6 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2) - A9F07206
Range Acti 9
Related Categories