TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 220 V AC coil  - LC1D09M7

Excl. Tax: €25.96 Incl. Tax: €25.96

Quick Overview - TeSys D - LC1D09M7

  • Main
    • range of product : TeSys D
    • range : TeSys
    • product name : TeSys D
    • product or component type : Contactor
    • device short name : LC1D
    • contactor application : Motor control
      Resistive load
    • utilisation category : AC-3
      AC-1
      AC-4
    • poles description : 3P
    • pole contact composition : 3 NO
    • [Ue] rated operational voltage : <= 300 V DC for power circuit
      <= 690 V AC 25...400 Hz for power circuit
    • [Ie] rated operational current : 25 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
      9 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
    • motor power kW : 2.2 kW at 400 V AC 50/60 Hz AC-4
      2.2 kW at 220...230 V AC 50/60 Hz AC-3
      4 kW at 380...400 V AC 50/60 Hz AC-3
      5.5 kW at 500 V AC 50/60 Hz AC-3
      5.5 kW at 660...690 V AC 50/60 Hz AC-3
      4 kW at 415...440 V AC 50/60 Hz AC-3
    • motor power hp : 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
      1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
      2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
      2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
      5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
      7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
    • control circuit type : AC 50/60 Hz
    • [Uc] control circuit voltage : 220 V AC 50/60 Hz
    • auxiliary contact composition : 1 NO + 1 NC
    • [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947
    • overvoltage category : III
    • [Ith] conventional free air thermal current : 25 A at <= 60 °C for power circuit
      10 A at <= 60 °C for signalling circuit
    • Irms rated making capacity : 250 A at 440 V for power circuit conforming to IEC 60947
      140 A AC for signalling circuit conforming to IEC 60947-5-1
      250 A DC for signalling circuit conforming to IEC 60947-5-1
    • rated breaking capacity : 250 A at 440 V for power circuit conforming to IEC 60947
    • [Icw] rated short-time withstand current : 105 A <= 40 °C 10 s power circuit
      210 A <= 40 °C 1 s power circuit
      30 A <= 40 °C 10 min power circuit
      61 A <= 40 °C 1 min power circuit
      100 A 1 s signalling circuit
      120 A 500 ms signalling circuit
      140 A 100 ms signalling circuit
    • associated fuse rating : 20 A gG at <= 690 V coordination type 2 for power circuit
      25 A gG at <= 690 V coordination type 1 for power circuit
      10 A gG for signalling circuit conforming to IEC 60947-5-1
    • average impedance : 2.5 mOhm at 50 Hz - Ith 25 A for power circuit
    • [Ui] rated insulation voltage : 600 V for power circuit certifications CSA
      600 V for power circuit certifications UL
      690 V for power circuit conforming to IEC 60947-4-1
      690 V for signalling circuit conforming to IEC 60947-1
      600 V for signalling circuit certifications CSA
      600 V for signalling circuit certifications UL
    • electrical durability : 0.6 Mcycles 25 A AC-1 at Ue <= 440 V
      2 Mcycles 9 A AC-3 at Ue <= 440 V
    • power dissipation per pole : 0.2 W AC-3
      1.56 W AC-1
    • protective cover : With
    • mounting support : Plate
      Rail
    • standards : CSA C22.2 No 14
      EN 60947-4-1
      EN 60947-5-1
      IEC 60947-4-1
      IEC 60947-5-1
      UL 508
    • product certifications : GL
      LROS
      CCC
      UL
      CSA
      BV
      RINA
      GOST
      DNV
    • connections - terminals : Control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
      Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end
      Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
      Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
      Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end
      Control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
      Control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
      Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
      Power circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end
      Power circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end
      Power circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
      Power circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end
    • tightening torque : Power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
      Power circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
      Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
      Control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
    • operating time : 4...19 ms opening
      12...22 ms closing
    • safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
      B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
    • mechanical durability : 15 Mcycles
    • operating rate : 3600 cyc/h at <= 60 °C

Details - Contactor - LC1D

  • Complementary
    • coil technology : Without built-in suppressor module
    • control circuit voltage limits : 0.3...0.6 Uc drop-out at 60 °C, AC 50/60 Hz
      0.8...1.1 Uc operational at 60 °C, AC 50 Hz
      0.85...1.1 Uc operational at 60 °C, AC 60 Hz
    • inrush power in VA : 70 VA at 20 °C (cos ϕ 0.75) 60 Hz
      70 VA at 20 °C (cos ϕ 0.75) 50 Hz
    • hold-in power consumption in VA : 7.5 VA at 20 °C (cos ϕ 0.3) 60 Hz
      7 VA at 20 °C (cos ϕ 0.3) 50 Hz
    • heat dissipation : 2...3 W at 50/60 Hz
    • auxiliary contacts type : Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
      Type mirror contact (1 NC) conforming to IEC 60947-4-1
    • signalling circuit frequency : 25...400 Hz
    • minimum switching current : 5 mA for signalling circuit
    • minimum switching voltage : 17 V for signalling circuit
    • non-overlap time : 1.5 ms on energisation between NC and NO contact
      1.5 ms on de-energisation between NC and NO contact
    • insulation resistance : > 10 MOhm for signalling circuit
    • motor power range AC-3 : 1.1...2 kW 200...240 V 3 phases
      2.2...3 kW 380...440 V 3 phases
      4...6 kW 380...440 V 3 phases
      4...6 kW 480...500 V 3 phases
    • motor starter type : Direct on-line contactor
    • contactor coil voltage : 220 V AC standard

Additional Information - LC1D - TeSys - LC1D09M7

Manufacturer Schneider
Code EAN 3389110348873
Plus d'infos
  • Environment
    • IP degree of protection : IP2x front face conforming to IEC 60529
    • protective treatment : TH conforming to IEC 60068-2-30
    • pollution degree : 3
    • ambient air temperature for operation : -20...60 °C
    • ambient air temperature for storage : -60...80 °C
    • permissible ambient air temperature around the device : -40...70 °C at Uc
    • operating altitude : 3000 m without derating in temperature
    • fire resistance : 850 °C conforming to IEC 60695-2-1
    • flame retardance : V1 conforming to UL 94
    • mechanical robustness : Vibrations contactor open 2 Gn, 5...300 Hz
      Vibrations contactor closed 4 Gn, 5...300 Hz
      Shocks contactor open 10 Gn for 11 ms
      Shocks contactor closed 15 Gn for 11 ms
    • height : 77 mm
    • width : 45 mm
    • depth : 86 mm
    • product weight : 0.32 kg
  • Offer Sustainability
    • Sustainable offer status : Green Premium product
    • RoHS (date code: YYWW) : Compliant  - since  0627  -  Schneider Electric declaration of conformity 
    • REACh :
    • Product environmental profile : Available
    • Product end of life instructions : Available
  • Contractual warranty