Quick Overview - TeSys GV3 - GV3P65

  • Main
    • range : TeSys
    • product name : TeSys GV3
    • device short name : GV3P
    • product or component type : Circuit breaker
    • device application : Motor
    • trip unit technology : Thermal-magnetic

Details - Circuit breaker - GV3P

  • Complementary
    • poles description : 3P
    • network type : AC
    • utilisation category : AC-3 conforming to IEC 60947-4-1
      Category A conforming to IEC 60947-2
    • network frequency : 50/60 Hz conforming to IEC 60947-4-1
    • mounting mode : By clips
      By screws
    • mounting support : Rail
      Plate
    • mounting position : Vertical
      Horizontal
    • motor power kW : 45 kW at 500 V AC 50/60 Hz
      55 kW at 690 V AC 50/60 Hz
      30 kW at 400/415 V AC 50/60 Hz
    • breaking capacity : 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
      100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
      50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
      6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
      12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    • [Ics] rated service short-circuit breaking capacity : 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
      100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
      50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
      50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
      100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    • control type : Rotary knob
    • [In] rated current : 48...65 A
    • trip unit rating : 48...65 A
    • magnetic tripping current : 910 A
    • [Ue] rated operational voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2
    • [Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2
    • [Ith] conventional free air thermal current : 65 A conforming to IEC 60947-4-1
    • [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947-2
    • power dissipation per pole : 8 W
    • mechanical durability : 50000 cycles
    • electrical durability : 50000 cycles for AC-3 at 440 V In
    • operating rate : 25 cyc/h
    • rated duty : Continuous conforming to IEC 60947-4-1
    • connections - terminals : EverLink BTR screw connectors 2 cable(s) 1...25 mm² - cable stiffness : solid
      EverLink BTR screw connectors 2 cable(s) 1...25 mm² - cable stiffness : flexible - without cable end
      EverLink BTR screw connectors 2 cable(s) 1...25 mm² - cable stiffness : flexible - with cable end
    • tightening torque : 5 N.m - on EverLink BTR screw connectors- cable 25 mm²
      5...8 N.m - on EverLink BTR screw connectors- cable 35 mm²
    • suitability for isolation : Yes conforming to IEC 60947-1
    • phase failure sensitivity : Yes conforming to IEC 60947-4-1
    • height : 132 mm
    • width : 55 mm
    • depth : 136 mm
    • product weight : 0.96 kg

Additional Information - GV3P - TeSys - GV3P65

Manufacturer Schneider
Code EAN 3389119405416
Plus d'infos
  • Environment
    • standards : EN/IEC 60947-2
      UL 508 type E
      EN/IEC 60947-4-1
      CSA C22.2 No 14-05 type E
      EN/IEC 60947-1
    • product certifications : CSA
      DNV
      BV
      EAC
      GL
      UL
      RINA
      CCC
      LROS (pending)
      ATEX
    • protective treatment : TH
    • IP degree of protection : IP20 conforming to IEC 60529
    • IK degree of protection : IK09
    • ambient air temperature for operation : -20...60 °C
    • ambient air temperature for storage : -40...80 °C
    • fire resistance : 960 °C conforming to IEC 60695-2-1
    • operating altitude : 3000 m
  • Contractual warranty
    • Warranty period : 18 months