calcActive())">
SCHNEIDER
controller M221 24 IO relay Ethernet - TM221CE24R
TM221CE24R
€331.62 Excl. Tax
€397.94 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 25 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 250€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
| Range of product: | Modicon M221 |
|---|---|
| Product or component type: | Logic controller |
| [Us] rated supply voltage: | 100...240 V AC |
| Discrete input number: | 14, discrete input conforming to IEC 61131-2 Type 1 |
| Analogue input number: | 2 at 0...10 V |
| Discrete output type: | Relay normally open |
| Discrete output number: | 10 relay |
| Discrete output voltage: | 5...125 V DC5...250 V AC |
| Discrete output current: | 2 A |
| Discrete I/O number: | 24 |
|---|---|
| Maximum number of I/O expansion module: | 7 for transistor output7 for relay output |
| Supply voltage limits: | 85...264 V |
| Network frequency: | 50/60 Hz |
| Inrush current: | 40 A |
| Maximum power consumption in VA: | 58 VA at 100...240 V with max number of I/O expansion module35 VA at 100...240 V without I/O expansion module |
| Power supply output current: | 0.52 A 5 V for expansion bus0.16 A 24 V for expansion bus |
| Discrete input logic: | Sink or source (positive/negative) |
| Discrete input voltage: | 24 V |
| Discrete input voltage type: | DC |
| Analogue input resolution: | 10 bits |
| LSB value: | 10 mV |
| Conversion time: | 1 ms per channel + 1 controller cycle time for analogue input analog input |
| Permitted overload on inputs: | +/- 30 V DC for 5 min (maximum) for analog input+/- 13 V DC (permanent) for analog input |
| Voltage state 1 guaranteed: | >= 15 V for input |
| Voltage state 0 guaranteed: | |
| Discrete input current: | 7 mA for discrete input5 mA for fast input |
| Input impedance: | 3.4 kOhm for discrete input100 kOhm for analog input4.9 kOhm for fast input |
| Response time: | 35 µs turn-off, I2...I5 terminal(s) for input10 ms turn-on for output10 ms turn-off for output5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input35 µs turn-on, other terminals terminal(s) for input5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input100 µs turn-off, other terminals terminal(s) for input |
| Configurable filtering time: | 0 ms for input3 ms for input12 ms for input |
| Output voltage limits: | 125 V DC277 V AC |
| Maximum current per output common: | 4 A at COM 27 A at COM 07 A at COM 1 |
| Absolute accuracy error: | +/- 1 % of full scale for analog input |
| Electrical durability: | 100000 cycles AC-12, 120 V, 240 VA, resistive100000 cycles AC-12, 240 V, 480 VA, resistive300000 cycles AC-12, 120 V, 80 VA, resistive300000 cycles AC-12, 240 V, 160 VA, resistive100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive100000 cycles DC-12, 24 V, 48 W, resistive300000 cycles DC-12, 24 V, 16 W, resistive100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms) |
| Switching frequency: | 20 switching operations/minute with maximum load |
| Mechanical durability: | 20000000 cycles for relay output |
| Minimum load: | 1 mA at 5 V DC for relay output |
| Protection type: | Without protection at 5 A |
| Reset time: | 1 s |
| Memory capacity: | 256 kB for user application and data RAM with 10000 instructions256 kB for internal variables RAM |
| Data backed up: | 256 kB built-in flash memory for backup of application and data |
| Data storage equipment: | 2 GB SD card (optional) |
| Battery type: | BR2032 lithium non-rechargeable, battery life: 4 year(s) |
| Backup time: | 1 year at 25 °C (by interruption of power supply) |
| Execution time for 1 KInstruction: | 0.3 ms for event and periodic task |
| Execution time per instruction: | 0.2 µs Boolean |
| Exct time for event task: | 60 µs response time |
| Maximum size of object areas: | 255 %TM timers512 %M memory bits8000 %MW memory words255 %C counters512 %KW constant words |
| Realtime clock: | With |
| Clock drift: | |
| Regulation loop: | Adjustable PID regulator up to 14 simultaneous loops |
| Counting input number: | 4 fast input (HSC mode) at 100 kHz 32 bits |
| Control signal type: | A/BSingle phasePulse/direction |
| Integrated connection type: | USB port with mini B USB 2.0 connectorNon isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface Ethernet with RJ45 connector |
| Supply: | (serial)serial link supply: 5 V, |
| Transmission rate: | 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS4851.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232480 Mbit/s for USB |
| Communication port protocol: | USB port: USB - SoMachine-NetworkNon isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-NetworkEthernet |
| Port Ethernet: | 10BASE-T/100BASE-TX 1 port with 100 m copper cable |
| Communication service: | Modbus TCP serverModbus TCP slave deviceDHCP clientModbus TCP clientEthernet/IP adapter |
| Local signalling: | 1 LED (green) for PWR1 LED (green) for RUN1 LED (red) for module error (ERR)1 LED (green) for SD card access (SD)1 LED (red) for BAT1 LED per channel (green) for I/O state1 LED (green) for SLEthernet network activity (green) for ACTEthernet network link (yellow) for Link (Link Status) |
| Electrical connection: | removable screw terminal block for inputs removable screw terminal block for outputs terminal block, 3 terminal(s) for connecting the 24 V DC power supply connector, 4 terminal(s) for analogue inputsMini B USB 2.0 connector for a programming terminal |
| Maximum cable distance between devices: | Shielded cable: Unshielded cable: Unshielded cable: Unshielded cable: |
| Insulation: | Between input and internal logic at 500 V ACNon-insulated between analogue input and internal logicNon-insulated between analogue inputsBetween supply and ground at 1500 V ACBetween sensor power supply and ground at 500 V ACBetween input and ground at 500 V ACBetween output and ground at 1500 V ACBetween supply and internal logic at 2300 V ACBetween sensor power supply and internal logic at 500 V ACBetween output and internal logic at 2300 V ACBetween Ethernet terminal and internal logic at 500 V ACBetween supply and sensor power supply at 2300 V AC |
| Marking: | CE |
| Sensor power supply: | 24 V DC at 250 mA supplied by the controller |
| Mounting support: | Top hat type TH35-15 rail conforming to IEC 60715Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit |
| Height: | 90 mm |
| Depth: | 70 mm |
| Width: | 110 mm |
| Net weight: | 0.395 kg |