Fast delivery - Satisfied or refunded for 14 days
9,6/10 out of 5668 reviews
✯ Have you spun our 100% winning gift wheel? Try your luck!
SCHNEIDER

Circuit breaker, ComPacT NS1600N, 50kA at 415VAC, 3P, fixed, manually operated, MicroLogic 2.0E control unit, 1600A - C160N32EFM

C160N32EFM

€4,043.14 Excl. Tax
€4,851.77 Inc. Tax
available In stock – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 250€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard paypal visa payplug fintecture alma applepay
Technical informations
Range: ComPacT
Product name: ComPacT NS new generation
Range of product: ComPacT NS630b...1600 new generation
Product or component type: Circuit breaker
Device application: Distribution
Poles description: 3P
Protected poles description: 3D
[In] rated current: 1600 A at 50 °C
[Ue] rated operational voltage: 690 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Suitability for isolation: Yes conforming to EN/IEC 60947-2
Utilisation category: Category B
Breaking capacity: 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-240 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code: N 50 kA 415 V AC
Trip unit name: MicroLogic 2.0 E
Trip unit technology: Electronic
Trip unit protection functions: LI
Control type: Manually operated
Mounting mode: Fixed
[Ui] rated insulation voltage: 800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity: 37 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-237 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-237 kA at 440 V AC 50/60 Hz conforming to IEC 60947-230 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-222 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current: 19.2 kA 1 s conforming to IEC 60947-2
Mechanical durability: 10000 cycles
Electrical durability: 1000 cycles at 690 V In2000 cycles at 690 V In/22000 cycles at 440 V In5000 cycles at 440 V In/2
Power losses: 74 W
Mounting support: Backplate
Upside connection: Front
Downside connection: Front
Connection pitch: 70 mm
Protection type: L
Trip unit rating: 1600 A at 50 °C
Long time pick-up adjustment type Ir: Adjustable 9 settings
Long time pick-up adjustment range: 0.4...1 x In
Long time delay adjustment type: Adjustable 9 settings
[tr] long-time delay adjustment range: 12.5...600 s at 1.5 x Ir0.5...24 s at 6 x Ir0.7...16.6 s at 7.2 x Ir
Thermal memory: 20 mn
Instantaneous pick-up adjustment type Ii: Adjustable
Instantaneous pick-up adjustment range: 1.5...10 x Ir
Earth-leakage protection: Without
Zone selective interlocking ZSI: Without
Auxiliary contact composition: 1 NO/NC
Local signalling: 4 LEDs (red) for fault indication1 LED (yellow) for overload
Display type: LCD display
Type of measurement: Energy meter
Width: 210 mm
Height: 327 mm
Depth: 147 mm
Net weight: 14 kg
Compatibility code: NS1600
In short
Reference C160N32EFM
Product Name Circuit breaker, ComPacT NS1600N, 50kA at 415VAC, 3P, fixed, manually operated, MicroLogic 2.0E control unit, 1600A - C160N32EFM
Range
Learn more
How do ComPacT NS circuit breakers ensure the safety of electrical installations?

How do ComPacT NS circuit breakers ensure the safety of electrical installations?

In the industrial sector, it is essential to ensure the safety of electrical installations in order to maintain continuity of operations, guarantee the safety of individuals and preserve equipment. Due to their complexity, these installations power various machines that are crucial for production, thus requiring electrical protection devices of particularly high reliability.

Read more
Related Categories