calcActive())">
SCHNEIDER
Acti9 iDD40T TG - RCBO - 1P+N - 40A - C Curve - 4500A/6kA - 30mA - type A-SI - A9DX2640
A9DX2640
€172.42 Excl. Tax
€206.90 Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock more than 25 units – Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 250€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
| Range: | Acti9 |
|---|---|
| Product name: | Acti9 iDD40 TG |
| Product or component type: | Residual current breaker with overcurrent protection (RCBO) |
| Device short name: | IDD40T TG |
| Device application: | Distribution |
| Poles description: | 1P + N |
| Number of protected poles: | 1 |
| Neutral position: | Left |
| [In] rated current: | 40 A |
| Network type: | AC |
| Trip unit technology: | Thermal-magnetic |
| Curve code: | C |
| Earth-leakage sensitivity: | 30 mA |
| Earth-leakage protection time delay: | Instantaneous |
| Earth-leakage protection class: | Type A-SI (Super Immunised) |
| Breaking capacity: | 4500 A Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-16 kA Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 |
| Suitability for isolation: | Yes conforming to EN/IEC 60947-2 |
| Quality labels: | NF |
| Device location in system: | Group incomer |
|---|---|
| Network frequency: | 50 Hz |
| [Ue] rated operational voltage: | 230 V AC 50 Hz |
| Magnetic tripping limit: | 5...10 x In |
| Residual current tripping technology: | Voltage independent |
| [Ics] rated service breaking capacity: | 4500 A 100 % x Icn at 230 V AC 50 Hz conforming to EN/IEC 61009-2-14.5 kA 75 % x Icu at 230 V AC 50 Hz conforming to EN/IEC 60947-2 |
| Rated breaking and making capacity: | Idm 3000 A at 230 V AC 50 Hz conforming to EN/IEC 61009-2-1 |
| Limitation class: | 3 conforming to EN/IEC 61009-2-1 |
| [Ui] rated insulation voltage: | 400 V AC 50 Hz |
| [Uimp] rated impulse withstand voltage: | 4 kV |
| Contact position indicator: | Yes |
| Control type: | Toggle |
| Local signalling: | ON/OFF indicationTrip indicator |
| Mounting mode: | Clip-on |
| Mounting support: | DIN rail |
| Comb busbar and distribution block compatibility: | Top or bottom: tooth |
| 9 mm pitches: | 4 |
| Height: | 91 mm |
| Width: | 36 mm |
| Depth: | 73 mm |
| Product weight: | 215 g |
| Colour: | White |
| Mechanical durability: | 20000 cycles |
| Electrical durability: | 10000 cycles |
| Locking options description: | Padlocking deviceSealable |
| Connections - terminals: | Tunnel type terminals top or bottom 1...16 mm² rigidTunnel type terminals top or bottom 1...10 mm² flexible |
| Wire stripping length: | 14 mm for top or bottom connection |
| Tightening torque: | 2 N.m top or bottom |
| Earth-leakage protection: | Integrated |